Installation Owner's manual
72 Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014
Appendix A Specifications and Dimensions
Table 9 - Performance Specifications for 200 mm frame size CHPS-Series Linear Stages
Performance Specifications for 250 mm frame size CHPS-Series Linear Stages
Cat. No. Slide Mass Continuous
(1)(2)
Peak Maximum
Static
Load
(3)
Max Static Moment Loads
(3)
Current Thrust Current Thrust Pitch Yaw Roll
kg (lb) A rms (Ao-pk) N (lbf) A rms (Ao-pk) N (lbf) kN (lbf) kN (lbf)
N•m (ft•lb) N•m (ft•lb)
CHPS-x8xxxD-xLMxxx 5.64 (12.4) 3.1 (4.3) 132 (30) 8.3 (11.7) 302 (68) 66 (14836) 171 9126) 412 (304) 270 (199)
CHPS-x8xxxE-xLMxxx 8.34 (18.4) 6.2 (8.7) 265 (60) 16.5 (23.3) 600 (135) 66 (14836) 270 (199) 620 (457) 270 (199)
CHPS-x8xxxF-xLMxxx 8.34 (18.4) 3.1 (4.3) 265 (60) 8.2 (11.6) 600 (135) 66 (14836) 270 (199) 620 (457) 270 (199)
(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%.
(3) Values apply to bearing rating only. Contact Applications Engineering for structural considerations.
Cat. No. Slide Mass Continuous
(1)(2)
Peak Maximum
Static Load
(3)
Max Static Moment Loads
(3)
Current Thrust CurrentThrust PitchYaw Roll
kg (lb) A rms (Ao-pk) N (lbf) A rms (Ao-pk) N (lbf) kN (lbf) kN (lbf)
N•m (ft•lb) N•m (ft•lb)
CHPS-x9xxxJ-xLMxxx 11.54 (25.4) 3.0 (4.2) 385 (87) 8.1 (11.5) 882 (198) 93.6 (21042) 170 (125) 385 (283) 508 (375)
CHPS-x9xxxK-xLMxxx 9.69 (21.4) 3.0 (4.2) 193 (43) 8.1 (11.5) 441 (99) 93.6 (21042) 324 (239) 734 (541) 508 (375)
CHPS-x9xxxL-xLMxxx 11.54 (25.4) 6.0 (8.5) 385 (87) 16.2 (22.9) 882 (198) 93.6 (21042) 324 (541) 734 (541) 508 (375)
(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%.
(3) Values apply to bearing rating only. Contact Applications Engineering for structural considerations.