Installation Owner's manual

Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014 71
Specifications and Dimensions Appendix A
Table 7 - Performance Specifications for 150 mm frame size CHPS-Series Linear Stages
Table 8 - Performance Specifications for 200 mm frame size CHPS-Series Linear Stages
Performance Specifications for 250 mm frame size CHPS-Series Linear Stages
Performance Specifications for 325V or 650V CHPS-Series Stage
Maximum cable length 10 m (33 ft). Please contact Applications Engineering
concerning application requiring longer cables.
Cat. No. Slide Mass Continuous
(1)
(2)
Peak Maximum
Static Load
(3)
Max Static Moment Loads
(3)
Current Thrust Current Thrust Pitch Yaw Roll
kg (lb) A rms (Ao-pk) N (lbf) A rms (Ao-pk) N (lbf) kN (lbf) kN (lbf)
N•m (ft•lb) N•m (ft•lb)
CHPS-A6xxxA-xLMxxx 4.64 (10.23) 2.3 (3.3) 80 (18) 7.0 (9.9) 239 (54) 38.0 (8722) 71 (52) 183 (134) 97 (71)
CHPS-A6xxxB-xLMxxx 6.48 (14.28) 4.7 (6.6) 160 (36) 14.0 (19.9) 479 (108) 38.0 (8722) 128 (94) 327 (241) 97 (71)
CHPS-A6xxxC-xLMxxx 6.48 (14.28) 2.3 (3.3) 160 (36) 7.0 (9.9) 479 (108) 38.0 (8722) 128 (94) 327 (241) 97 (71)
(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%
(3) Values apply to bearing rating only. Contact Applications Engineering for structural considerations.
Cat. No. Slide Mass Continuous
(1)
(2)
Peak Maximum
Static Load
(3)
Max Static Moment Loads
(3)
Current Thrust Current Thrust Pitch Yaw Roll
kg (lb) A rms (Ao-pk) N (lbf) A rms (Ao-pk) N (lbf) kN (lb) kN (lbf)
N•m (ft•lb) N•m (ft•lb)
CHPS-A8xxxA-xLMxxx 4.59 (10.1) 2.1 (3.0) 72 (16) 6.3 (8.9) 215 (48) 66 (14836) 171 9126) 412 (304) 270 (199)
CHPS-A8xxxB-xLMxxx 6.58 (14.5) 4.2 (6.0) 144 (32) 12.6 (17.9) 431 (97) 66 (14836) 270 (199) 620 (457) 270 (199)
CHPS-A8xxxC-xLMxxx 6.58 (14.5) 2.1 (3.0) 144 (32) 6.3 (8.9) 431 (97) 66 (14836) 270 (199) 620 (457) 270 (199)
(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%.
(3) Values apply to bearing rating only, Contact Applications Engineering for structural considerations.
Cat. No. Slide Mass Continuous
(1)(2)
Peak Maximum
Static Load
(3)
Max Static Moment Loads
(3)
Current Thrust Current Thrust Pitch Yaw Roll
kg (lb)
A rms (Ao-pk)
N (lbf) A rms (Ao-pk) N (lbf) kN (lbf) kN (lbf)
N•m (ft•lb) N•m (ft•lb)
CHPS-A9xxxG-xLMxxx 8.58 (18.9) 1.9 (2.7) 109 (25) 5.8 (8.2) 328 (74) 93.6 (21042) 170 (125) 385 (283) 508 (375)
CHPS-A9xxxH-xLMxxx 9.62 (21.2) 3.8 (5.4) 219 (49) 11.5 (16.3) 656 (147) 93.6 (21042) 324 (239) 734 (541) 508 (375)
CHPS-A9xxxI-xLMxxx 9.62 (21.2) 1.9 (2.7) 219 (49) 5.8 (8.2) 656 (147) 93.6 (21042) 324 (541) 734 (541) 508 (375)
(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%.
(3) Values apply to bearing rating only. Contact Applications Engineering for structural considerations.