Installation Owner's manual
Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014 29
Mounting the Stage Chapter 4
1940 mm stroke length = 194.0 cm
Determine the Type of Fastener to Use
Three types of fasteners that can be used to mount the stage.
• Through bolts
• Toe clamps
• Tee nut or square nut
Toe clamps are supplied with the catalog number CHPS-x6xxx stages, and
covered types of the catalog number CHPS-x8xxx and CHPS-x9xxx stages.
Refer to the Mounting Fastener Options
table for an illustration of each fastener
type.
Table 1 - Mounting Fastener Options
fasteners 19 1+202× 40 fasteners===
fasteners
194 cm + 36
12
----------------------------------
230
12
--------- 1 9 . 1 6 7===
round down 19=
Fastener Order Illustration User Supplies
(4)
Recommended For
Torque
N•m (lbf•in)
Through Bolt
(1)
– M5 x 1.0 x 16 mm min Uncovered stages 2.3 (30)
Toe clamps MPAS-TOE M6 x 1.0 x 16 mm min Covered stages 5.5 (48)
Tee nuts
(2)
MPAS-x-TNUT
(3)
M6 x1.0 Securing a stage from
beneath the mounting
surface.
Tee Nut 6.7 (60)
Square Nut 2.3 (30)
(1) Through bolt mounting is not an option for catalog number CHPS-x6xxxx-xLMxxx (150 mm) stages.
(2) The tee nut mount for a catalog number CHPS-x8xxxx-xxxxx (200 mm) stage is a square nut in a tee slot.
(3) Where x is the frame size of a stage, 6 = CHPS-x6xxxx-xxxxx (150 mm), 8 = CHPS-x8xxxx-xxxxx (200 mm), 9 = CHPS-x9xxxx-xxxxx (250 mm).
(4) You supply the bolts.