Installation Owner's manual

Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014 29
Mounting the Stage Chapter 4
1940 mm stroke length = 194.0 cm
Determine the Type of Fastener to Use
Three types of fasteners that can be used to mount the stage.
Through bolts
Toe clamps
Tee nut or square nut
Toe clamps are supplied with the catalog number CHPS-x6xxx stages, and
covered types of the catalog number CHPS-x8xxx and CHPS-x9xxx stages.
Refer to the Mounting Fastener Options
table for an illustration of each fastener
type.
Table 1 - Mounting Fastener Options
fasteners 19 1+202× 40 fasteners===
fasteners
194 cm + 36
12
----------------------------------
230
12
--------- 1 9 . 1 6 7===
round down 19=
Fastener Order Illustration User Supplies
(4)
Recommended For
Torque
N•m (lbf•in)
Through Bolt
(1)
M5 x 1.0 x 16 mm min Uncovered stages 2.3 (30)
Toe clamps MPAS-TOE M6 x 1.0 x 16 mm min Covered stages 5.5 (48)
Tee nuts
(2)
MPAS-x-TNUT
(3)
M6 x1.0 Securing a stage from
beneath the mounting
surface.
Tee Nut 6.7 (60)
Square Nut 2.3 (30)
(1) Through bolt mounting is not an option for catalog number CHPS-x6xxxx-xLMxxx (150 mm) stages.
(2) The tee nut mount for a catalog number CHPS-x8xxxx-xxxxx (200 mm) stage is a square nut in a tee slot.
(3) Where x is the frame size of a stage, 6 = CHPS-x6xxxx-xxxxx (150 mm), 8 = CHPS-x8xxxx-xxxxx (200 mm), 9 = CHPS-x9xxxx-xxxxx (250 mm).
(4) You supply the bolts.