Installation Instructions User guide

Bul. 937C Strain Gauge Converter Installation Instructions
Range
This parameter is required for evaluations in the unit %.
Under Set displays, enter the value that is to correspond to the gross value 100 % in the (before
selecting %) selected unit kg, N, cbm
or pcs (see section 7.2). Values between 0 and the maximum
cell load are possible.
Alternatively, you can select Execute and then Yes after excitation of the cell (e. g. after applying
a corresponding weight). This stores the current measured value as Range.
After a change to the unit %, the gross value is calculated as follows:
kg/unit
This menu option is only displayed if N, cbm or pcs has been selected as unit (see section 7.2) or
if % has been selected as unit and N, cbm or pcs has been selected previously.
The entered value determines the conversion of kg into
N (approx. 1/9.81 = 0.102)
cbm (known from the application or to be determined by weighing)
pcs (known from the application or to be determined by weighing).
If % has been selected as unit, the factor for converting kg into the previously selected unit must
be entered.
If an adjust into a unit other than kg is performed, the value kg/unit must be entered before the
adjust. After changing the value kg/unit, a new adjust is required.
Gross value in %
Range
---
Gr
-----------
oss va
-----------
l
------
ue
-----
wi
------
th
------
ou
--------
t ch
-----------
ang
------
e
--------
to %
------
× 100 %=
22