USER MANUAL APS 6.0

Preface
Advanced Programming Software User Manual
5–6
SLC 5/02, SLC 5/03, and SLC 5/04 processors – You have the option of
configuring generic I/O modules having 8, 16, or 32 discrete I/O. For example,
if you select 1746-I*8, any 8-point discrete input module may be used.
7. Select a module for the indicated slot number by positioning the cursor on the
desired module and pressing either
CONFIG
OFFLINE
CONFIG
SELECT
MODULE
F2
or [ENTER]. The cursor is
already correctly positioned in this case. The I/O configuration display
reappears.
8. Repeat the procedure until you have configured all of the required I/O.
9. Once you have configured all of your I/O press
CONFIG
OFFLINE
CONFIG
EXIT
F8
or [ESC], then
CONFIG
OFFLINE
CONFIG
SAVE &
EXIT
F8
. The following display appears:
Name Size Date
CONVEYOR 8847 08-18-95
DRILL1 9392 09-12-95
EXAMPLE 929 10-07-95
MIXER 10221 10-15-94
ONOFF 9334 08-04-95
PAINTGUN 9261 07-19-94
RPMCALC 8704 04-27-94
SEQUENCE 8684 10-03-95
STOP_GO 8586 09-28-94
TOGGLE 8695 07-19-94
C:\IPDS\ARCH\SLC500
F6 F7F1
CREATE
FILE
DEFINE
DIR
OFFLINE
PRG/DOC
NEW ARCHIVE FILE CREATED
Press a Function Key or Enter File Name
F9
SAVE
TO FILE
The
message line indicates
NEW ARCHIVE FILE CREATED. The name
EXAMPLE, along with the size and date appear in the right-hand window. This
file is now in the terminal workspace.