QUICK START GUIDE APS 6.0 User Manual
Additional Ladder Program Exercises
A–7
T
ype
0
then press
[ENTER]. This is the Timer Accumulated Value.
(EN)
(DN)
TON
TIMER ON DELAY
Timer T4:0
Time Base 0.01
Preset 1000
Accum 0
] [
I:1
0
END
3. Accept the rung.
Press
[ESC], then
CONFIG
OFFLINE
CONFIG
ACCEPT
RUNG
F10
.
4. Enter a second rung and an XIC instruction.
Press
CONFIG
OFFLINE
CONFIG
INSERT
INSTR
F4
, then
CONFIG
OFFLINE
CONFIG
BIT
F1
, then
CONFIG
OFFLINE
CONFIG
XIC
-] [-
F1
. T
ype the address
T4:0/TT
then press
[ENTER]. “TT” represents the timer timing bit.
(EN)
(DN)
] [
I:1
0
TON
TIMER ON DELAY
Timer T4:0
Time Base 0.01
Preset 1000
Accum 0
] [
T4:0
TT
( )
O:3
3
END
5. Enter an OTE instruction.
Press
CONFIG
OFFLINE
CONFIG
BIT
F1
, then
CONFIG
OFFLINE
CONFIG
OTE
-( )-
F3
. T
ype the address
O:3/3
, then press
[ENTER].