GETTING STARTED Owner manual
Setting Up ControlNet to RIO Block Transfer Pass Thru Communications 8-9
2.
In the
Options
menu, select
Communication Setup
. The
Communication
Setup
dialog box appears.
3.
Click the
ControlNet
tab.
4.
Under
Connect Type
, select
KFC to ControlNet Phase 1.5 to PLC RIO
Pass-Thru
.
5.
In the
Enter INTERCHANGE Port Mapping
field, type the number of
the KT:0 port used by the ControlNet driver in the RSLinx
Configure
Client Applications
dialog box.
Important:
To view the KT Port number used by the ControlNet driver, select
Configure Client Applications
in the RSLinx
Communications
menu.
6.
If you are using a 1336 FORCE and its drive firmware version is 0.10,
select
1336T Two Word Header (used ONLY for 1336T version 0.10)
.
7.
Click
OK
. The following prompt appears.
8.
Read the information, and then click
OK
to save the configuration.