GETTING STARTED Owner manual

Overview 1-5
Using DriveTools32 with an Allen-Bradley SCANport-Compatible Product
You can use DriveTools32 with many Allen-Bradley SCANport-compatible
products. For a list of Allen-Bradley SCANport products, refer to Appendix A,
Products Supported by DriveTools32
. If you use DriveTools32 with one of these
products, you have the following options:
Communications Required Drive Hardware Required Computer Hardware Refer To:
RS-232 Point-to-Point Serial Serial Adapter (1203-SSS, 1203-GD2,
1203-GK2, or 1336-GM2) & appropriate cable(s)
RS-232 port Chapter 3
DH+ to RIO Block Transfer
Pass Thru (PLC or SLC)
Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)
1784-KT, -KTX, -KTXD, or -PCMK Chapter 6
RS-232 to ControlNet Direct ControlNet Adapter (1203-CN1) & appropriate
cables
1770-KFC & RS-232 port Chapter 7
ControlNet Direct ControlNet Adapter (1203-CN1) & appropriate
cables
1784-KTC, -KTCX, or -PCC Chapter 7
RS-232 to ControlNet to RIO
Block Transfer Pass Thru
(PLC)
Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)
1770-KFC & RS-232 port Chapter 8
ControlNet to RIO Block
Transfer Pass Thru (PLC)
Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)
1784-KTC, -KTCX, or -PCC Chapter 8
RS-232 to DeviceNet Direct DeviceNet Adapter (1203-GK5, 1203-GU6,
1336-GM5, or 1336-GM6) & appropriate
cable(s)
1770-KFD & RS-232 port Chapter 9
DeviceNet Direct DeviceNet Adapter (1203-GK5, 1203-GU6,
1336-GM5, or 1336-GM6) & appropriate
cable(s)
1784-PCD or -PCIDS Chapter 9
Ethernet to RIO Block Transfer
Pass Thru
Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)
Ethernet Interface Running TCP/IP Chapter 10
RSLinx Gateway Server:
Ethernet to DH+ to RIO Block
Transfer Pass Thru
Remote I/O Adapter (1203-GD1, 1203-GK1 or
1336-GM1) & appropriate cable(s)
Client:
Ethernet Interface Running TCP/IP
Server:
Ethernet Interface Running TCP/IP and
1784-KT, -KTX, -KTXD, or -PCMK
Chapter 11
RSLinx Gateway Server:
Ethernet to ControlNet Direct
ControlNet Adapter (1203-CN1) & appropriate
cables
Client:
Ethernet Interface Running TCP/IP
Server:
Ethernet Interface Running TCP/IP and
1784-KTC, -KTCX, or -PCC
Chapter 11
RSLinx Gateway Server:
Ethernet to RS-232 Point-to-
Point Serial
Serial Adapter(1203-SSS, 1203-GD2,
1203-GK2, or 1336-GM2) & appropriate cable(s)
Client:
Ethernet Interface Running TCP/IP
Server:
Ethernet Interface Running TCP/IP and
RS-232 port
Chapter 11
Modem (Serial) Serial Adapter (1203-SSS, 1203-GD2,
1203-GK2, or 1336-GM2), appropriate cable(s),
null modem converter, and modem
RS-232 port and modem Chapter 12
ControlLogix Equipment depends on network to which the
drive is connected.
Equipment depends on network to which the
computer is connected.
Chapter 13
ControlLogix to RIO Block
Transfer Pass Thru
Remote I/O Adapter (1203-GD1, 1203-GK1 or
1336-GM1) & appropriate cable(s)
Equipment depends on network to which the
computer is connected.