User guide

Publication 900-UM007D-EN-E - January 2011
A-4
Table A.A (Continued)
General/Environmental (Continued)
Ambient Humidity Relative humidity 25…85% (no condensation)
Storage Temperature –25…+65°C (with no condensation or icing)
Altitude 2,000 m or less
Installation Environment Installation Category II, Pollution Class 2 (IEC 61010-1 compliant)
Recommended Fuse T2A, 250V AC, time lag, low shut off capacity
EMC EMI EN 61326
Radiated Interference Electromagnetic
Field Strength
EN 55011 Group 1, class A
Noise Terminal Voltage EN 55011 Group 1, class A
EMS EN 61326
ESD Immunity EN 61000-4-2
Electromagnetic Field Immunity EN 61000-4-3
Burst Noise Immunity EN 61000-4-4
Conducted Disturbance Immunity EN 61000-4-6
Surge Immunity EN 61000-4-5
Power Frequency Magnetic Field
Immunity
EN 61000-4-8
Voltage Dip/Interrupting Immunity EN 61000-4-11
Standards & Certifications UL61010-1, CSA22.2 No. 1010.1; ULus
IP66. Conforms to EN61326, EN61010-1