Parameter Functions & Definitions 5-39
Related Parameters
PID ON/OFF, Standard or Heating/Cooling (Initial Setting function
group, page 5-55)
Soak Time
Conditions of Use: The Program Pattern parameter must NOT be set to
OFF.
Function: This parameter enables you to configure the soak or delay time for
the control operation when using the simple program function.
Related Parameters
Program Start, Soak Time Remain (Operation function group, page
5-15)
Wait Band (Adjustment function group, page 5-40)
Program Pattern (Initial Setting function group, page 5-57)
Soak Time Unit (Advanced Setting function group, page 5-96)
Table 5.AQ
Parameters Controller Type
Configurable
Range Units Default
Hysteresis (heating) With Thermocouple or Resistance Thermometer (RTD) 0.1…999.9 °C or °F 1.0
With Analog Inputs 0.01…99.99 %FS 0.10
Hysteresis (cooling) With Thermocouple or Resistance Thermometer (RTD) 0.0…999.9 °C or °F 1.0
With Analog Inputs 0.01…99.99 %FS 0.10
Set NONE as the unit for Controllers with 0…50 Millivolt Inputs.
Table 5.AR
Configurable Range Units Default
1…9999 Minutes or hours 1
soak