Software
7–21Using ODS Communication Configuration
Publication MCD-5.1 -August 1999
C. Double click the Services control panel to view the available
services.
D. Locate and highlight the Remote Access Server. Click
Start.
10.Click Dial to connect to the 9/PC host (server PC) from your
ODS workstation (client PC).
Troubleshooting Tips for RAS Configuration
If you receive the message “Error 651” when establishing a
connection, the first items to check are:
• cable pinouts are correct and have continuity
• Cable connections are good to the PC serial ports
• The port you have connected the cable to actually corresponds to
the port name you have configured (e.g.,COM1 vs COM2).
• Baud rates and other port settings for the configured ports must
be the same on the client and Server PCs
• Baud rates up to 115,200 have been successfully used on short
cable lengths.
If you have any further questions after reading this manual, contact
Allen-Bradley Software Support Services at (440) 646-6800.