Owner's manual
OffsetTable and Setup
Chapter 3
3-23
5. Data can be replaced or added to as follows:
To replace stored travel data with new data, key-in the new data
and press the
{REPLCE VALUE} softkey.
To add to previously stored travel data, key-in the amount to be
added a nd press the
{ADD TO VALUE} softkey.
(softkey level 4)
REPLCE
VALUE
ADD TO
VALUE
UPDATE
& EXIT
QUIT
6. To end editing the programmable zone parameters there are two
choices.
Press t he {UPDATE & EXIT} softkey to store the changes made to
the parameters and leave the programmable zone screen.
Press t he {QUIT} softkey to delete all changes made to the
programmable zones and leave the programmable zone screen.
(softkey level 4)
REPLCE
VALUE
ADD TO
VALUE
UPDATE
& EXIT
QUIT
Use this feature to change the values set for the single digit feedrates.
When a single digit F--word is encountered during block execution, the
control looks to the single digit feedrate table for a feedrate. T he feedrate
in this table corresponding to the single digit then becomes the active
feedrate. For details on programming single digit F--words see chapter 28.
Important: Feedrates must always be entered into the single digit feedrate
table in units of inches per minute (IPM) or millimeters per minute
(MMPM) dependent on the controls current feedrate mode.
1. Press t he
{SYSTEM SUPORT} softkey.
(softkey level 1)
PRGRAM
MANAGE
OFFSET MACRO
PARAM
QUICK
CHECK
SYSTEM
SUPORT
FRONT
PANEL
ERROR
MESAGE
PASS-
WORD
SWITCH
LANG
3.6
Single Digit Feedrate Table