Owner's manual
Error and System Messages
Appendix B
B-43
Message Description
THREAD LEAD IS ZERO Nothread leadhas beenprogrammedin a blockthatcalls forthread cutting. Threadleadis
programmed with eitheran F-oranE-word.
THREAD PULLOUT DISTANCE TOO LARGE The programmed threadingpulloutdistanceis largerthan the programmed distance ofthe
thread departure.
THREAD PULLOUT STOPPED AT I--PLANE The chamferblockofa threading cycle isshortened sothatthe combination ofpulloutangle and
pulloutdistancedoes notcause the retractin axis1 togo beyondtheI--plane. TheAMPpullout
angleis stillusedforthe chamfer.
THREADINGDISTANCEISZ ERO A threadingcycle hasbeen programmedwithno thread. Programan end-pointoran end-point
different fromthe start-point.
TIME-OUT OCCURRED WHILE WAITINGFOR INPUT When downloading AMP or PALfromtheODSworkstation to the control,the message OKAY
TODOWNLOAD? (Y/N):appearson thecontrol screen. Ifyou do notrespond within an allowed
time,this errorwill appear.
TIMERMUSTSTART WITH # You have used incorrect search string syntaxin thePAL searchmonitorutility.
TOO MANY( [)IN EXPRESSI ON T he controlhas found anunmatched numberof[]ina programblockorcalculatoroperation. All
leftbrackets “[”musthavea correspondingrightbracket“]”.
TOO MANY( ])IN EXPRESSI ON T he controlhas found anunmatched numberof[]ina programblockorcalculatoroperation. All
rightbrackets “]”musthavea corresponding leftbracket“[”.
TOOMANY 7300 PATTERNSINMEMORY Anattemptwas madeto enter a7300 pattern into the control’smemory when the internal
cross-reference table ofpattern repeat nameswas full. The internalcross-referencetable of
patternrepeatnames can onlyhold 20patternrepeatnames.
TOO MANYACTIVE PROCESSES CONFIGURED An AMPhas beenloaded thathas toomanyactively configuredprocesses forthiscontroller
model. The 260seriesandthedual lathe can haveonly 2 active processes.
TOO MANYAXES AMPEDFOR HARDWARE AnAMPhasbeen loadedthathastoo manyconfiguredaxes forthis controller model.The
9/440 series canhave only upto6 axes.
TOO MANYAXES PROGRAMMED Too many axisletters were programmedin a fixed cycle block.
TOO MANYAXES SELECTED FOR DISPLAY Whenusing the {AXIS SELECT}softkey,you candisplayonly6 axes. Ifyou attempt todisplay
more than 6axes,this message isdisplayed.
TOO MANYCODES INSYNCH BLOCK Synch codesmust be ina blockbythemselves,exceptforan N-orO-word. (9/260-9/290 dual
lathe only)
TOO MANYDECIMALPOINTS Awordorparametervaluehas beenprogrammedwith two ormore decimalpoints.
TOO MANY DEVICESON I/O RING T he I/Oringcannotsupportthe numberofdevicesthathasbeenconnected.
TOO MANYEXPRESSION NESTS T he maximumnumberofnestedexpressions is25;for example,[P3+[P4+[P5]]]has 3
expressions nests.
TOOMANY G67’S AG67 cancelmodalparamacrocodewas executedwhen nomodalparamacrowas active.
Thisis typically causedwhen therearefewer nestedmodalparamacrosthantheprogrammer
expected.
TOO MANYI-J-KSETS Anattemptwas madeto define alocal paramacro parameterthatisgreaterthan#33 using I,J,K,
argumentsets. Amaximumof10 differentI,J,K,sets may beprogrammedforeachsetoflocal
parameters.
TOO MANY MACRO CALLS T he maximumnumberofnested paramacros was reached. Only4 paramacros canbe activeat
anyone time.
TOOMANY MOTORSAMPEDON 1ST BOARD The AMP parameterforthe number ofmotors on the firstservo board islarger than the number
ofaxes in the system.
TOO MANYNESTED (DO) COMMANDS Morethan the allowable numberparamacro DOloops are activeatone time. Amaximumof3
nested DOloops are allowed.
TOO MANYNONMOTION BLOCKS-DEADLOCK T here were too many non-motion blocks encounteredduringthelook-ahead for cutter
compensationorQPP. ConsultAllen-Bradleycustomersupportservices.