Owner's manual
Error and System Messages
Appendix B
B-35
Message Description
PROGRAMNOT FOUND The programcannotbelocatedinmemory. Check to make sure the programnamewas
correctly entered.
PROGRAM OPEN FOR EDIT INANOTHER PROCESS On a dual-processing system,you cannotedit a programthat is active inanotherprocess. You
willneedtoswitch processes ifyou wantto edittheother program.
PROGRAMREWINDERROR An attempttorewind the tape wasnotsuccessful. Check tobe sure thatthetapereaderis
functioningproperly and the tape ison the drive sprockets.
PROGRAM SHOULD START HERE When performinga {MID STPRGRAM}operationtorestartaprogram,thecontrolhas found the
blockthatthe programexecutionshould begin at, and selected thatblockas the nextblockto
be executed. Thatblockis the block immediately following the onecontaining an @.
PROGRAMMED AXIS I SOFF OR DET ACHED Partprogramblocksare attempting to programmotions on an axis thathas itsservoseitheroff
orconfiguredas detached inAMP.
PROGRAMMED G26 DEPTH < TRIGGER TOLERANCE AG26 block isprogrammedwith anintegrand less than orequaltotheAMPed AdaptiveDepth
TriggerToleranceamount. Ablockdecode errorisgivenand the blockwillnotexecute untilthe
integrandin the blockismadelargerorAMPis modified to reduce thetriggertolerance.
PROGRAMMED SPINDLE UNAVAILABLE The programmerattempted to programthefollowerspindleindependently (M03,M04,M05,or
M19)while spindle synchronization wasactive.
PROGRAMSARE DIFFERENT A programverifyoperation has determined thatthetwoselected programsarenotidentical.
PROGRAMS ARE IDENTICAL Aprogram verify operationhas determined thatthe two selectedprograms are identical
matches.
PROGRMABLE ZONE 2 VIOLATION Anattemptwasmadetomovetheindicated axis into the area defined byprogrammable zone2.
PROGRMABLE ZONE 3 VIOLATION Anattemptwasmadetomovetheindicated axis into (oroutof)the area defined by
programmable zone3.
PROGRMD G26 DEPT H <TRIGGERTOLERANCE Theprogrammedadaptive depth deflection(hole depth)is lessthan the probetolerancevalue.
Youmusteitherincrease the programmed blockdepth, or decreasetheAMPed probetolerance
value.
Q
QPP ANGLE WORD SAMEAS AXISNAME AMPhasdownloadedan anglewordforQuickPath Plusthat is the same asan axis name.
AMP mustbe reconfigured;the anglewordcannotbe the same asan axis name.
QPPBLOCKFORMAT ERROR Data isincorrectly enteredor insufficientdataisentered for the control to correctly executea
QuickPath Plus block orpair ofQuickPathPlus blocks.
QPP MDIBLOCK LOOKAHEAD ERROR Only one oftwo necessary blocks was programmed inMDIusing QuickPathPluscommands
that require two blocksfor properexecution.
QPPNOT ALLOWED DURING POLARMODE With polarcoordinate programming active,youcannotuse QPP.
R
RWORDFORMATFINERTHAN The word formatprogrammed is requestinga finerresolutionthan the axiswordformatforthe
correspondingaxis allows. These word formatsare setin AMP.
RAPID SPEED TOO HIGH FOR AMPEDCONFIG AMPconfigurationerror. The axisresolutionsand feedbackdeviceresolutionswillnotpermit
the rapid and maximum feedrates assigned inAMP.
RADIUSTOOSMALL Anarc(orhelix) was programmed (G02 orG03)thatdefinesa radius thatistoosmallto connect
the start-pointofthe arc to the end-point. The valueofRis too small.
RAPID TOO HIGH FOR AMPED CONFIG AMPconfigurationerror. The axisand feedbackdeviceresolutionswillnotpermittherapid
feedratesassignedinAMP.
RAPID TRAVERSE ERROR : Anattemptwasmadetojogan axisusingrapidtraversewhenitisnotpermitted. Typically,to
usetheTRVRS function while jogging,the controlmustbe inmanualmode;continuousjog
mustbe selected;and,ifthe axisbeingjogged hasan overtravelvalue,thataxis mustfirsthave
been homed.
READ ERROR Anattemptto read aprogramfromatapeordiskdrivehas failed.