Owner's manual

Error and System Messages
Appendix B
B-34
Message Description
POCKET IS P ART OF CUSTOMTOOL Anattemptwasmadetoassigna tool toa tool pocketthatisalreadyusedby acustom tool.
Customtoolsareassignedtotoolpockets thatareshownwith an XXXXnextto the pocket
numberontherandomtool table.
POCKET MILLING SHAPE IS INVALID A parameter is missing in the G88programmingblock.
POINT ALREADY EXISTS The pointthatyou are trying to enteris already in the axiscalibrationtable.
PORTBISBUSY Thismessage appearswhenyou press {SYSTEM SUPORT},{MONITOR},or{SERIAL I/O}and
portBisbusy.
PORT I SBUSY -REQUEST DENIED Anattemptwasmade tooutputor inputinformation to orfromaserialcommunications portthat
isalreadybeingused bysomeotherdevice orisselected astheportthatan activeprogram is
coming from.
PREVIOUS ABORT COMMAND NOT COMPLETE T his message is displayed whenthecommunications abort”keyis entered before the lastabort
requested has completed.
PROBE/CONTROLLINGAXISCARD DIFFERENT Boththe adaptivedepthprobeand the adaptive depth probecontrolling axis (typicallythe axis
that positions the probe)mustbe attached to the same servo card. Youmustre-AMP your
systemandre-arrangeyourservo wiringso thattheadaptive depth probe andit’scorresponding
servoareonthesameservocard.
PROBE CYCLES CALCULATION ERROR T he servo module wasunabletocompute the probe position when the probeisfired. Make
surethatall measurementpoints are within theprogrammedrangeentered for the probe cycle.
Lowerthe feedrate during the probing operation and try again.
PROBE CYCLES PROGRAMMINGERROR Eithernotenough ortoomanyaxes are programmed ina probing cycleblock.
PROBEERROR A probing cyclehas reached the outerlimits of thetolerance band withoutfiringtheprobe,orthe
probehas fired before entering the toleranceband.
PROBE INUSE BYOTHER PROCESS On adual processingcontrolonly oneprobingfunctionis allowed at any onetime. Probing can
notbe performedby both processessimultaneously. You must waitforprobing to complete in
one processbefore probing intheotherprocess.
PROBE ISARMED,CANT ADJUST SERVOS With the probe armed througha probing operation,untilthe probefiresortheprobe is disarmed,
other online AMP servoparametersliketorque,feedforward percentage,gain,etc.,arenot
allowedtobe changed.
PROBETRIPDURINGDECEL An adaptivedepthprobetrip occurredaftertheprogramblock reached endpoint. The tripwas
madewhilethecontrolwas waitingforthe followingerrortocollapseafterinterpolation is
complete. Avoid this errorbyreducing axisspeed (thusreducing followingerror)orby moving
the adaptive depth blockendpointfurtherintothepart.
PROCESSSWITCH NOT CURRENTLY ALLOWED On a dual-processingsystem,you cannotswitch processes whilein graphicsor in digitize.
PROGRAM ACTIVE Anattempthasbeen made to delete orperform some otheroperationtoa programthatwas
activatedforautomaticexecution. The programmustbe deactivatedusingthe{CANCEL
PRGRAM} softkey.
PROGRAM ACTIVE I NANOTHER PROCESS This duallathe errorappearswhenone process attemptstoopen afile foredit,deletion,etc.,
whilethatfileisactive inanotherprocess.
PROGRAM BEING EDITED Anattempthasbeen made to copy,verify,or performsomeotheroperationon aprogramthatis
stillin the editmode. Itisnecessarytopress the {EXIT EDITOR}softkey fromtheeditmenu to
properly end an editingoperation.
PROGRAMBLOCKTOOLONG More than 128 characterswereentered into asingleblock.
PROGRAMCURRENTLYINUSE Asubprogram orparamacro programwas called thatiscurrentlybeingused to performsome
other operation(such asediting orcopying). Typically,thismessage isthe resultofattempting
to editaprogram thatwasnotproperly closed. Aprogramremains intheeditmodeuntil the
{EXITEDITOR}softkey ispressedfromtheprogrameditmenu.
PROGRAMNAMETOOLONG An attemptwas made to create a programwitha programnamelongerthan8 alphanumeric
characters. Ifa large,descriptiveprogram name is desired,a commentmay beadded to the
rightoftheprogramname using the{PRGRAMCOMENT}feature.