Owner's manual
Error and System Messages
Appendix B
B-31
Message Description
O
OBJECT NOT FOUND IN PROGRAM The objectyouare searching forin thesearchmonitor utility does notexistinthecurrent
module, or does notexist in the programin thedirection you aresearching.
OCI ETHERNET CARD NOT INSTALLED AnOCIdual--process systemhas a standard CRT installed. The OCIEthernetcard hasnot
been installed. Thismayhappen ifadual--processOCIexecutive is loadedinto a non--OCI
system.
OCI SYSTEMERROR VRTXerror. ContactAllenBradley Support.
OCI PROCESSING TASK OVERLAP T he amountof time to process anew OCI requestistaking longerthan expected. T his isan
informational warningonly. Iti snotcritical to theCNC.
OCI WATCH LIST TASK OVERLAP This messageindicates thatthewatch listtaskwas notrunningtocompletionin the AMPed
allottedamountoftime. Thistypically occurswhen alargetask isrequested by anOCIstation
and the CNC takeslongerthanexpected to complete.
ODS &9/SERIESREVISIONS DI FFER The version ofAMPor PAL on the peripheraldevice does notmatchthecontrol version.
ODS RUNG MONITOR ACTIVE The online PAL search monitorutilitycan notbe accesse d. The online PAL search monitor
utility requirestheoffline O DS PAL search monitorutilitytonotbe running.
OFFSET EXCEEDS M AXCHANGE You haveattempted to modifyan offsettable byan amountthat is largerthantheallowable
changetoan offsettable. Referto yourAMP reference manual fordetails on Maximumwear
and geometry offsetchange.
OFFSET EXCEEDS M AXVALUE You have attemptedtomodify anoffset tableby enteringan offsetamountthatis largerthanthe
allowable maximumoffsetselected inAMP. Referto yourAMPreferencemanualfordetailson
Maximumoffsettablevalues.
OFFSET MOTION PENDING ON CYCLESTART Afterchangingthe active offsetthismessageidentifiesthatthecontrol will move the axis to the
new offsetlocation the nexttimecycle sta rtis pressed (this ma y ormay notoccur on a
non-- motion blockdependingon the AMP offsetconfiguration).
OFFSET TABLE(S) CORRUPT/CLEARED Abad offsettable checksum value was detected bythe control during PTO.
ONLYONE DEPTH PROBE PER SERVO BOARD The 9/Series servo card firmware onlysupports one adaptive depth probe on each servo card.
Ifyour systemrequires more than oneadaptive depth probetheymustbeattached to different
servo cards (9/230and 9/440 controlscan only haveone adaptivedepthprobe). AMP mustbe
configuredtoindicate which portthe adaptivedepthprobeisattached to.
ONLYONE M19 ALLOWED PER BLOCK For syste m configured with multiple spindles, onlyone spindle orientM-code (M19)is allowed
perblock.
ONLYREQUEST THE DUAL MASTER FOR JOGS Anattemptwasmadeto joga slaveaxis;you canjog aslaveaxis only whenthemasteraxisis
parked.
OPTION NOTINSTALLED Anattemptwasmadeto programan optional feature thathasnotbeen purchased from
Allen-Bradley.
OPTION NOT INSTALLED (PAL DISPLAY PAGE) The PAL display pageoption isnotinstalled on yourcontrol.
OPTIONAL FEATURE ISNOT PROVIDED An attemptwas made to programanoptionalfeature thathas notbeenpurchasedfrom
Allen-Bradley.
OPTIONAL RAMSIMMBAD/MISSI NG The control hasdiscovered the RAM SIMMsforthe extended storageoptionareeither
damagedormissing. TheRAMSIMMsmustbe installedorreplaced. ContactyourAllen
Bradley sales representativeforassistance.
OTHERPROCESSG CODECONFLICT On a dualprocessingsystem,one process hasa conflicting Gcode active whenyou attempted
toactivate a G26 depth probe cycle. Fo r e xample,processone executes a G26 while process
two hasan axisinfeedtohardstopwhichison the same servo card asthedepthprobe.
OVER SPEED A servomotor is turningatan RPMthatisgreaterthanthe maximumRPMallowed forthat
servo as defined in AMPby th e systeminstaller. Fordig ital spindles this error can result from
maximumRPMgearrange 1 being sethigherthan your AMPedallowedMaximumMotor
Speed.