Owner's manual

Error and System Messages
Appendix B
B-24
Message Description
LARGER MEMORY - REFORMAT This message typically occurs afteranew AMPorPALhas justbeen downloadedto the control.
Thereis now more memory available fortheRAMdisk,but you needtoreformatto use it. If
desired,you donothave to reformatRAMand cancontinue torunthecontrolwith the RAMdisk
atits currentsize.
LEAD WORD FORMAT FINERTHAN The word formatprogrammed is requestinga finerresolutionthantheaxiswordformatforthe
correspondingaxis allows. These word formatsare setin AMP.
LENGTH OFFSET AXISMISSI NGIN PROCESS Youhave configuredthetool length axis asa shared axisand itis currentlynotbeing controlled
bytheprocessrequestingtoactivatea tool length offset.The shared length axis mustbe
returnedtotheprocess attemptingtoactivatethetooloffset. Or tooloffsets wereprogrammed
for anaxisthatis configuredin AMPas unfitted.
LESS MEMORY -REFORMA T Thismessagetypicallyoccursaftera new AMP or PAL has justbeendownloadedtothecontrol.
Thereis now lessmemoryavailablefor the RAMdisk,andyou mustreformatto use the RAM
disk.
LETTERORDIGITMUSTFOLLOW$,%,!,&,OR# You have used incorre ct searchstring syntax inthe PAL search monitorutility.
LETTERORDIGITMUSTFOLLOW$,%,!OR# You have used incorrectsearchstringsyntax inthe PAL search monitorutility.
LETTEROR DIGITMUST FOLLOW $,%OR! You have used incorrect searchstring synta x in the PALse archmonitorutility.
LETTEROR DIGITMUST FOLLOW $,%OR! You have used incorrect searchstring synta x in the PALse archmonitorutility.
LETTEROR DIGITMUST FOLLOW # You have used incorrectsearchstringsyntax inthe PAL searchmonitorutility.
LIMITEXTRN DECEL SPEED ON Dualaxes have limitedtheexternaldecel speedAMP value. Anaxisin the dual-axisgroupwas
AMPed witha lowervalue.
LIMIT MANUAL DLY CONSTNT ON Dual axeshavelimitedthemanualdelay constantAMPvalue. An axis inthedual-axis group
wasAMPed with alowervalue.
LIMITMAX CUTTING FEED ON Dualaxes havelimitedthemaximumcuttingfeedrateAMPvalue. Anaxis in the dual-axisgroup
wasAMPed with alowervalue.
LIMITED ACC/DEC RAMP ON Dualaxeshave limited the acc/dec rampAMPvalue. Anaxisin the dual-axisgroup was
AMPed witha lowervalue.
LIMITED RAPID FEEDRA TE ON Dual axeshavelimitedtherapidfeedrateAMPvalue. Anaxisin the dual-axisgroup was
AMPed witha lowervalue.
LIMITEDVELOCITYSTEPON Ifthe velocitystepAMP value isnotthesamefor all axesofa dualgroup,the control will adjust
themtothe limiting axis.
LOW VOLTAGE ON FLASH STICKS CallAllen-Bradley SupportServices.
LOWER > UPPER A value entered inthe programmable zonetable for zone2 or 3resultsin alowerlimitvalue
beinggreater than theupper limit. Theupperlimitmustalways begreater than thelowerlimit.
M
M02 OR M30 FOUND -REQUEST TERMINATED Thiserror occursifan M02 orM30 isfoundbefore the requestedblockwhilesearching during a
mid-programstart. The search will beterminated atthe M02/M30 block.
MACHINE HOMEREQUIRED OR G28 Anattemptwasmade to programan axismove before the axeswere homed. Axescan be
homedmanually orbyprogramminga G28 block.
MASTER HAS TO BE AMPEDFIRST The dualmasteraxishas to beconfigured firstin the AMPdata base.
MASTER ONLYG-CODE -- MUST PARK SLAVES Anattemptwasmadetoprograma G-code thatis notcompatible with a dualaxes. The
programmed G-code canonly beappliedtotheAMPdefined masteraxis ofthe dualaxisgroup.
Allother axes inthedualaxis group mustbe parked.
MATHOVERFLOW Yourparamacroorcalculatorfunction is requiringa calculationwith anexcessively large or
illegalvalue.
MAXSIZE EXCEEDED The programmed numberofsymbols istoolarge (the communicationdatapacketistoolarge).
MAXSOLID TAP RPMEXCEEDS MAXGEAR RPM The resultingsolidtaping RPMexceeds the spindles currentRPM Maximumfortheactive gear
range. Eitherchange gearranges,orreducethetapping speed.