Owner's manual

Error and System Messages
Appendix B
B-22
Message Description
INVALID PROGRAM NUMBER (P) Aprogram numbercalledby asub-programorparamacrocallis invalid. A P-wordthatcalls a
sub-programorparamacrocanonly bean all-numericprogramname asmanyas 5digits long.
The O-wordprecedingthe numeric programnumberin controlmemorycannotbe enteredwith
the P-word.
INVALID REMOTENODENAME Anerroroccurred inG05 DH+ communications block.
INVALID REMOTE STATION TYPE Anerroroccurred inG05 DH+ communications block.
INVALID REPEAT COUNT (L) An Lparameterthatprograms thenumberoftimesa paramacroorotheroperationistobe
repeated was programmed incorrectlyor outofthelegal range. T he L-word forrepeatcount
mustbe a whole,positive number. Decimal values andnegative valuesareinvalid. The
maximumvalueofan L-wordis 9999.
INVALID ROUGHING CYCLE (P/Q) WORD V ALUE When executing aroughingcycle,thestartingorending sequence numberofthe contour
defining blocks cannotbefoundinthecurrentlyexecuting program. The sequence numberof
the contour blocks is programmed using the Pand Qwords. These blocks can beanywherein
the programprovidedtheyareresidentin the same program,sub-program,orparamacro
programthatcontains the calling block.
INVALIDSCALE FACTOR (P-WORD) An invalid scale factorhasbeen specified. The P-wordhas a rangeof0.0001to 999.99999.
INVALID SERVO HARDWARE TYPE TheAMPservo parameterthatselects the servotypedoes not match the hardware found on
the controlwhen the AMPfile isdownloaded. Either AMPismisconfiguredortheservo
hardware installed on yoursystemis notcorrectly installedo r notofthe correct type.
INVALID SHAFT POCKET Whenentering acustomtool in the random tooltable,anattemptwas madeto assigna shaft
pocketpositionthatisnotintherangeofthenumberofpocketsassigned tothetool. The shaft
pocketnumber mustbeequal to orlessthan the numberassigned forthenumberofpockets.
INVALID SHAFT POCKET VALUE Aprogram is attemptingtoenteracustom toolin the randomtooltable with ainvalidshaft
pocketposition(notintherangeofthenumberofpocketsassignedtothetool). Theshaft
pocketnumber mustbeequal to orlessthan the numberassigned forthenumberofpockets.
The shaftpocketvalue isassignedin aG10.1blockfollowing the R-word.
INVALID SPCMD VALUE A invalid special commanderror typically occurs when the servo PROMs are notcompatible
with the main processorPROMs. Check the software version numbersand contact
Allen-Bradley customersupportservices.
INVALID SYMBOL NAME An erroroccurred in G05DH+ communicationsblock.
INVALID T-CODEFORMAT This isan invalid T-Code Format
INVALID_THREAD_ANGLE Anattemptwasmadetoprograman anglethatisoutside the allowable range,whichis 0
through 120degrees.
INVALIDTHRESHOLDRATE Aninvalid thresholdpercentage wasentered fora tool group while setting tool management
data. The thresholdpercentage mustrange between 0and 100percent. Onlywholepositive
numbers canbe entered. If using aG10 block,thethreshold percentageisentered with a
Q-word.
INVALIDTIMEFORMAT MUST BE HH:MM:SS Aninvalid time formatwasentered. The time formatmustbe hour /minute/second
(HH/MM/SS).
INVALID TOOL AXIS This is an invalid Tool Axis.
INVALID TOOL CUTTER COMPENSATION NUMBER Anattemptwasmade to enteratoolradius offsetnumber,forcuttercompensationorTTRC,in
the tool life managementtable thatislargerthan the maximumoffsetnumberallowed. Ifthe
tables are beingloaded bya G10 program,the radius offsetis enteredwitha D-word inthe
block.
INVALID TOOL DIAMETER VALUE An invalidtooldiametervaluewas enteredin aprogramblock.
INVALID TOOL GROUP Anattemptwasmadeto create a tool group greaterthan200 inthe tool managementtables. A
maximumof200 toolgroupscan beused. Ifloadingthetables usinga G10 program,the tool
groupnumberisentered using aP-word.