Owner's manual

Error and System Messages
Appendix B
B-21
Message Description
INVALID FIXED DRILLING AXI S The axis selected asthedrilling axisis aninvalid axisfora drilling application.
INVALID FORMAT SPECIFIED IN B/DPRNT CMD Improperformatwasusedin the paramacro command (BPRNT orDPRNT) thatoutputsdatato
a peripheraldevice.
INVALIDFUNCTION ARGUMENT Aninvalidparamacroargumentwas usedin a paramacrofunction. The argumentcontains
eitherbad syntax oranillegalvalue.
INVALID G10CODE T he formatfora G10blockis not correct. Referto yourusermanual forthecorrectformatfor
the G10 block thatiscurrentlybeingprogrammed.
INVALIDINANGLEDWHEELMODE A feature thatisnotavailablein G16.3 mode,orG16.4modeorbothhas beenprogrammed.
Refer toyourgrinderusers manual angled-wheelgrindersection fora description offeatures not
available on an angled-wheel grinder.
INVALIDINFEED(P WORD) Infeed value (P-word)is not in valid range. The valid range for a P-wordduringa threading
cycleis whole numbers 1though4.
INVALIDINPUT VALUE The data enteredis invalidforthe currentoperationbeing performed.
INVALIDINTERFERENCEAREA AG10 blockhasprogrammeda zonewheretheplusvalue is lessthan the minus value.
INVALIDINTERFERENCECHECK AXIS Anaxisfrom the wrongprocesswasAMPed. Unlessa shared axis is usedin the zone,the axis
defined to make upan interferenceareamustbein the process thezone isdefined for.
INVALID LATHE AXIS Anillegalcode wasencounteredduringcylindricalinterpolation programming.
INVALID LIFE TYPE Thecurrentprogram is attemptingtoenteraninvalidtoollife type fora toolgroupin the tool
managementtables. Valid toollife types are type 0,1,or2. Tool life typeis programmed in a
G10blockfollowingaI-word.
INVALID M99 IN MAIN PROGRAM An M99 part programrewind and auto startwasprogrammedinthemiddleofthemain program.
AnM99can beprogrammedonlyattheend ofapartprogram.
INVALIDMACRO COMMAND The ISand IM commandsarereserved foruseby the controlonlyforprograminterrupts. T hey
cannotbeentered ina partprogramorMDIprogram.
INVALID MACRO FROMTAPE You haveprogrammeda paramacro commandthatcannotbeexecuted fromtape.
INVALID NUMBER OF POCKETS This erroroccurs whenusing G10 L20 toenterrandomtooldataand the numberofpockets
needed forthetool isinvalid.
INVALID OFFSET NUMBER An offsetnumberoutoftherangeofallowableoffsetnumbers(eithertoo large ortoo small)was
programmed.
INVALID OPERATOR INEXPRESSION Check expressionstomakesuretheyarecorrect.
INVALID OPERATOR INP ARAM ACRO EXPRESSI ON The controlhas encountered a non-mathematicaloperator (character) in a paramacro
expression orcalculateoperation.
INVALID OUTPUT FORMAT An erroroccurredin G05 DH+communications block.
INVALID PARAM ACRO ARGUMENT ASSIGNMENT Anargument assignmentin a block thatcallsa paramacro programcontains eitheran invalid
argumentspecification orasyntaxerrorwas made intheargument.
INVALID PARAM ETER NUMBER An attemptwasmade toassign or read the valueofa paramacro parameter thatdoesnotexist.
INVALID PARAM ETER VALUE An attemptwasmadetoassignan invalid value(typically too large ortoo small ofavalue)to a
paramacroparameter.
INVALID POCKET NUMBER Anattemptwasmadeto enteratoolpocketnumberthatexceeds the allowable number oftool
pockets inthe randomtool table. This erroroccurs whena P-word thatis too large ortoo small
isprogrammedin a G10.1L20 block.
INVALID POCKET PROFILE An invalid pocketprofile was programmed in a lathe roughingorfinishing cycle.
INVALID POSITION FB TYPE Systemwasincorrectly AMPedwith a Yaskawatypeencoder(absolute or incremental)onthe
position feedbackdevice when separateposition andvelocity feedback devices are used.