Owner's manual
Error and System Messages
Appendix B
B-15
Message Description
FLASH SI M MS CONTAININVALID DATA Flash SIMMs havebecome corrupted probably fromacommunicationerrorduring asystem
update. Retry the systemexecutiveupdateutility. If the situationpersists, contact
Allen--Bradley support.
FLASH SI M MS U10 AND U14 ARE EMPTYOR
MISSING
Make sureyo urflash SIMMsare installed inthe correct tracks.Refertothe 9/Series integration
and maintenance manual section coveringyourprocessor fordetails on flash installation.
Remove andreseatflash SIMMs.
FLASH SI M MU10 ISEMPTY OR MI SSING Makesure your flash SIMMs are installed inthecorrecttracks. Ifthey appearto be installed
correctly,remove andreseatSIMMs. Ifproblem persists,contactAllen -- Bradleysupportservice.
FLASH SI M MU14 ISEMPTY OR MI SSING Makesure your flash SIMMs are installed inthecorrecttracks. Ifthey appearto be installed
correctly,remove andreseatSIMMs. Ifproblem persists,contactAllen -- Bradleysupportservice.
FLASH WRITE ERROR A problemoccurred while writing to flash,forexample bad flash,no flash,orno voltage.
FOREGROUND OVERLAP Th e foregroundtasksdid notcomplete execution within the 20-millisecond period allocated.
Foreground tasks include PALforeground,axisinterpolation,servo interface,and I/Oring
scanning. CorrectbyreducingPALforegroundprogram size orremovingsomedevicesfrom
the I/O ring.
G
G10 NOT ALLOWED DURING CYCLE G10 code is notallowed tobe used during the cycle. Cancel the fixed cycle.
G24 NOT ALLOWED G24 isnotallowedwhen anyautomaticG codedcycle is active (such as G81).
G24 PLANE INCOMP A TIBILITY The hard stop axismaynotbein the activepartrotation plane.
G25 NOT ALLOWED G25 isnotallowedwhen anyautomaticG codedcycle is active (such as G81).
G25 PLANE INCOMP A TIBILITY The adaptive feed axis may notbein theactive partrotation plane.
G26 NOT ALLOWED G26 (adaptivedepthprobe)cannotbe programmed when another modalgroup is active(such
asaG81fixedcycle).
G26 PLANE INCOMP A TIBILITY Aconflictbetweena plane dependentfeatureand a G26 (depthprobe). Forexample ifpart
rotation isactive anda G26is programmedon anaxis in the partrotationplane this erroris
generated. Refertothe 9/Seriesusersmanual section on G26 fordetails onincompatible
planarfeatures.
G28 BLOCK DOESNOT PRECEDEG29 BLOCK A G29 block was programmed beforea G28 block. During 7300 tape compatibilitymode,the
firstautomatic threadingblockmustcontaina G28code;thenextblockmustcontaina G29
code.
G29 BLOCKDOESNOT FOLLOWG28 BLOCK AG28 blockwas programmed withouta following G29block. During 7300 tape compatibility
mode,the firstautomaticthreading block mustcontain aG28 code;the nextblock mustcontain
a G29 code.
G40 NOT ALLOWED IN CIRCULAR An exitmovefromcuttercompensationor T TRC wasattempted in acircular block (G02 orG03).
Anexitmove (programmed witha G40)mustgenerate alinearmove.
G53 NOT ALLOWED IN G91MODE Anattemptwasmadeto makean incrementalmovein the machine (absolute)coordinate
system. Only absolute moves (G90)are permittedin the machine coordinate system.
G53 NOT ALLOWED IN INCREMENTAL MODE A G53movetoabsolute position was requestedwhilein incrementalmode.
G53 ON ANUNHOMEDAXES An attemptto programa movein the machine (absolute)coordinate system wasmade before
the axiswashomed. Itisnecessary to home the axestoestablish the locationofthemachine
coordinatesystem.
G91 MODENOT ALLOWED INQPP SinceQuickPath Plus isgenerally usedto programblockswithoutknowing the intersection of
theblocks,itisimpossible tocalculate alocationforthe end-point of the b lock whenthemove is
incremental. QuickPathPlusmustbeprogrammed inabsolutemode(G90).
(G-CODE) TABLE ERROR Therehas beenan internalsoftware faultrelativetotheG-codetable. ConsultAllen-Bradley
CustomerSupportServices.
(GOTO)SEQ.NUMBERNOT FOUND The sequencenumber(N word)calledby aGOTOcommanddoesnotexistinthecurrently
executing program.