Owner's manual

Error and System Messages
Appendix B
B-12
Message Description
DRESSER W ARNINGLIMIT REACHED The axisspecified as the dresseraxis has beendressedsmaller than thedresserwarning limit
valueas specifiedon the dresserstatuspage.
DRILLAXISCONF IGURATION ERROR The drillingaxis isnota currentlyconfigured machine axis. On dualprocessing controlsthis
messagemayresultwhenthedrilling axisis inanotherprocess. The drillingaxis must bea
configuredaxisin the currentprocess andshouldnotbe the slave ofa dual axis(drillaxis
shouldbe the masteraxisfor dual group). On machineswithdualaxes,this message can
meantheaxis configuredin AMP asthefixed-drillingaxis isa slave axis. Th e drillaxis should
be the master axis.
DUAL AXES MASTER&SLAVE PROCESS NOT SAME Whenconfiguring adual axis ona dualprocessingsystem,configure AMP soallaxes inthe
dualaxis group are inthe same source process evenifthe dualaxisgroup is shared.
DUAL AXES PARKLOGIC CANNOT CHANGE Anattemptwasmade,using dualaxes,to changethecurrentparkstatus. Atthis point,the
request willnotbe allowed.
DUAL GROUP AXESMUST HAVE SAMEROLLOVER All rotary axesin a dualaxes group musthave the same rollovervalue. These rollovervalues
aresetinAMP.
DUAL LATHE-MUST USE PROCESS1,2 Duallathe musthave the activeprocesses bethefirst2 available in AMP;3 or 4shouldnotbe
configuredas anactive process.
DUAL MASTER&SLAVE RAD/DI AMCONFIG ERR The slave ofadual group hasbeen defined as a diameter axis. T he OEMmustdefinethe
masterto be a diameteraxis and thesystemwillchange the slavetobe adiameteraxis. When
the groupisdecoupled theslave willcontinue to take onthemaster’s rad/diamtraits.
DUAL PLANECONFIGURATIONERROR In AMP you havedefineda plane with anaxisand amaster and a slave in the wrong order. For
example: Ifthe systemhas 4axes YXZU andZU are duals,ifanAMPed plane is ZX,then UX
cannotbe andAMPed plane. Itmustbe XU (referto your AMPreferencemanualfordetails).
DUAL SLAVE OR SPLIT AXIS NOT ALLOWED Neithera dualslave,norasplitaxis (deskew axis) maybe programmed ina G24,G25,orG26
block.
DUALS CANNOT CHANGE OFFSETS IN CIRCULAR Anattemptwasmade,using dualaxes,to accountforan offsetchange ina circularmove.
Dualoffsetchanges canonlybe madeinlinear blocks.
DUALS ONLY ALLOWINGSINGLEAXISHOME An attemptwasmadetohome multiple axes ina dualgroupwhen PALonlyallowsone axisata
time tobe homed. PAL canbe changed to allowhoming ofmultipleaxesin adual group.
DUALPORT PTOTEST F AILED The Dualportfailed the diagnostic testandthebootstrapping operationis skipped. Consult
Allen-Bradley customersupportservices.
DUPLICATE 1394 SLOT The 1394rackID andslotnumberAMPentries are the same fortwoormore servos. Each axis
module ina 1394rackmusthavean individualaddress.
DUPLICATE 7300 PATTERNNAME An attemptwasmadetoentera7300 pattern name thatalreadyexists.
DUPLICATE DUALMASTER NAMES Bothdual master axes names havethesameletter.
DUPLICATE I/O RING DEVICE Two or moreofthesametype ofdeviceon the I/O ring havethesamedeviceaddressswitch
setting.
DUPLICATE PROGRAM An attemptwas made to renamea programin control memoryusingthesameprogramname
(ornumber)ofanother programalready in memory.
DUPLICATE PROGRAMNAME Anattemptwasmadeto store or copyaprogramin controlmemory using the same program
name(ornumber)ofanother programalready inmemory.
DWELL VALUE NOT PROGRAMMED AG04 Dwellor a parameterrequesting a dwell at hole bottomin afixed drilling cyclewas
programmed with novalueassigned to thelengthofthedwell.
E
(E) AND (F) IN SAME BLOCK In a G32 block (LatheA)orG33 block (LatheB & C),bothleadswereprogrammedin thesame
block.
EMPTY PROGRAM W ASDELETED FROM DIRECTORY The currentprogrambeing edited wassaved and conta ined no programblocks. This program
wasdeletedfromthecontrol’s programdirectory.