Error and System Messages
Appendix B
B-11
Message Description
DEPTH PROBE TRAVELLIMIT T he adaptive depth probe hasmovedtoits AMPed travel limit. Note the valueentered inAMP
istheadaptive depth probedeflectionfromthePAL determined probe zero point. Itmaynotbe
the actual totalprobedeflection.
DEPTH PROBE NOT SUPPORTED Adepth probeaxishas been AMPed onan axis located ona servo card ora9/230thatdoes
notsupporttheadaptivedepth feature. (analog servo rev< rev0.10or 3 axis9/2609/290
digital servocards)
DESKEW OPTION NOT INST ALLED Ifthe AMPedname specifying the deskewslaveservo isnotzero,orthe AMPedname
specifyingthedeskewmaster servois not zero,andtheoptionflag for deskew iszero,thenthe
systemis h eld inE-Stop.
DEVICE ALREADY OPENED An attemptwasmade to open a device fordownloador upload fromportsA orBwhenthe
devicewasalreadyopened.
DEVICE NOT OPENED YET The ready signalwasnotreceived whenattempting to senddata to orcommunicate with a
peripheraldevice connectedtocommunication portsA orB.
DIAMETER AXI SMISCONFIGURED An invalidaxis has beenconfigured asthediameteraxis.
DIRECTORYCHANGED TO MAIN DIRECTORY Whena passwordis enteredthatdoes nothaveaccesstotheprotectable part program
directory andtheprotectablepartprogramdirectory iscurrently selected,the controlchanges
the selected directory to the main directory.
DISPSELECT NOT ALLOWED You can notuse the display selectfunctionswhile the online PAL search monitorutility is active.
Leave the search monitorutility before youtry to selecta display.
DIVIDE BY ZERO ERROR Asystemsoftware errorhas occurred. ConsultAllen-Bradley customersupportservices.
(DO) NUMBERALREADY USED When executinga program,anattemptwas made to activatea DO loopthathasthesameloop
identifier (DO 1,2,or3)asan alreadyactive loopin the program. Provided they are not nested
loops,the same loopidentifiercanbe used more than onceina program.
(DO)RANGESINTERSECT DOloops are improperly nested. ADOloop thatisnestedwithin anotherDO loop doesnot
havean ENDcommand beforethe original DOloopENDoccurs.
DRESSCANCEL DEFERREDTOG40 The in -- processdressercannot be canceled(made inactive)while dresser/wheel radius
compensationisactive. Ifan attempt tocancel the in--processdresser is made,the control will
postpone the requestuntildresser/wheel radius compensation iscanceledwith aG40 (notethat
M02,M30,and M99 canalsocancel compensation).
DRESSER AXISNOT ALLOWED An attemptwasmadetoprogram the dresseraxiswhentheoverthewheeldresserfeature has
been activated throughPAL. Youcannotprogramthedresseraxis whentheoverthewheel
dresser feature is active.
DRESSER FLANGE LIMI TREACHED While dressingthegrinding wheelthewheelsizereachedtheentered flange limit. Youshould
stop dressing the wheelbefore damage to thewheel flange occurs.
DRESSER MI NI MUM LIMI TREACHED The currentdressing operationwoulddressthegrinding wheelbelowtheminimumwheel
diameterasspecified onthedresserstatusscreen. Thisdressing operationwillnotbe
performed.
DRESSER MI SCONFIGURED One ofthe AMPparameters for thedresseraxishasnotbeen configuredproperly. Eitherthe
dresseraxis, the vertical axis,or some otheraxis name is nota valid axis in the system. You
mustre-configure yourAMP. Refer to yourAMPmanualfordetails.
DRESSER MI S- POSI TIONED Wheelre-enablewas requestedwith IPDactive and wheel ismore than 4inch-programming
counts (hard-code amount)awayfrom itspreviously activeabsoluteposition. Wheeldressing
doesnotstart.
DRESSER NOT INITIALIZED Thiserroris generatedifan attemptismadetoactivatethein-- processdresserbeforethe
dresser has beeninitialized througha wheel calibration operation.
DRESSER NOT/MIS CONFIGURED Thegrinderover-the-wheeldresser feature issues thismessagewhena wheelisinitialized and
the dresser parametersin AMPhavebeen misconfigured. Thismessage isissuedwhen the
dresser axis,dresser vertical axis,ordresserotheraxishas notbeenselected,orhas been
AMPed to havecommon axes,or has beenAMPed tobe a non-existentaxis name.