Owner's manual

Error and System Messages
Appendix B
B-7
Message Description
CANNOT RENAME Whenperforming arename ofaprogramname,thenew programname hasnotbeen correctly
entered. TheformatisOLD PROGRAMNAME,NEWPROGRAM NAME.
CANNOT REPLACE START POINT Anillegalattemptwas made to changetheaxiscalibrationstart-pointusingtheonlineAMP
feature.
CANNOT RESTART G24 HARDSTOP Anattemptwasmadetorestartapartprogramon a blockwhichwouldhave anaxisatthehard
stop. Youcannotrestartormid startapartprogramafterif(atthatblocks execution)anyaxis
wouldbe holding againstahardstop. Youmusteitherre-start/mid--starttoa blockbefore the
G24 hard stop block orto ablockafterthehardstopisreleased.
CANNOT SENDAVAILABLE COMMAND Thisis displayed when a non-programmedcommunications commandisexecutedfrom
send’¨softkey .
CANNOT SET DATA WHEN TOOL ISACTIVE Anattemptwasmadetomanually (using the softkeys)change tool managementdata forthe
currently active tool. Tool managementdata canbe changedonly fora toolthatisnotcurrently
selected asthe active tool.
CANNOT TAPIN CSS You mustdisabletheCSSfeaturebefore youbegina tapping operation. DisableCSSusinga
G97 command.
CANNOT TAPIN VIRTUAL-C MODE You attempted to use the solidtappingfeaturewhile cylindrical orend-face milling was active.
CANNOT UPLOAD -PAL NOTINPROM PALcan beuploaded onlyfromthePAL PROMs. PALin RAMmemorycannotbe uploaded.
CANNOT UPLOAD- PAL SOURCENOT LOADED Whenthesourceisloaded,PAL canbe uploadedinthe9/240only . The 9/260 and9/290
alwayshavePALin flash.
CANNOT USE COPY WITH ACTIVE TOOL OFFSET Anattemptwasmadetocopyoffsetdata fromoneaxis toanotherusingthe{COPY OF F SET}
softkey. You cannotusethissoftkeyifthe tool offsets are active.
CANNOT USEEXIT - BL OCK NOT FOUND An attemptwas made to {EXIT}whilesearching for ablockforamid-program start. You cannot
use{EXIT}until the blockhasbeen found. To abortthesearch,use {QUIT}.
CANNOT WRITE AREAD-ONL YPARAMETER An attemptwas made to assign ava lue to a PAL orsystemparamacroparameterthatis a
read-only parameter. The value ofthese parameterscan beused only bytheprogrammer;they
cannotbealtered intheprogram.
CANNOT WRITE TO PROGRAM Thisindicates aseriousproblem withtheprogram. Attemptto write to programa second time.
If retry doesn’twork,youmayhavetodeletetheprogram. Typicallythis errorisnotcaused bya
programmer or operatoraction,butratherbyan internalprogram softwareerror.
CAUT ION! YOUAREIN7300TAPEMODE
TORET URN TO STANDARD 9/240 MODE
RESET THE 7300-- COMPATIBILITY PALFLAG
The operatoriscautioned thatthetapebeing copied ispresumed to be a 7300 formattedtape.
Thismessageis displayedon the copy-tapeset-up screen whenthe MCU isin 7300
compatibilitymode.
CC/TTRC ON,CAN’T ASSIGN TIMEDEP.PARAM An attemptwasmade to assign a time-dependentparamacrosystemparameterwhile
dresser/wheelradiuscompensation was active. Time-dependantparametersareany system
parameters thatrecord orreference a current axis position.
CHAMFERLENGTH/RADIUS TOO LARGE Achamferor radiusvalue programmedwitha ,Cor,Rwouldgenerate a chamfer or radius that
islargerthan oneorbothofthetwo adjacenttool paths.
CHAMFER/RADIUSNOT ALLOWED An attemptwas made to performa chamferorradius cut(programmedwith a ,Ror,C)ina
blockthatdoesnotallowthese functions to beperformed. Forexample,you cannotdoa
chamferorradiuscutina non-motion block,in the lastblock on an MDIline,orin thelastblock
ofa partprogram.
CHANGENO T MADEINBUFFERED BLOCKS Changestotheoffset tabledid notaffect thoseprogram blocks thatwerealready inthecontrol’s
currentactivation queue. Program blocks thatcallfor offsets andwhichfollow those already in
the activation queue willcall theupdatedoffsettables.
CHANNELNAME TOO LONG Thereisan errorin G05 DH+communications block.
CHARMUST BE_,.,LETTER,DIGIT You have used in correctsearchstringsyntax inthe PAL searchmonitorutility.
CHARMUST BELETTER,DIGIT,UNDERSCORE You have used incorre ct searchstring syntax inthe PAL search monitorutility.
CHARACTERSMUST BEDIGIT You have used incorrect searchstrin g syntax in the PAL search monitorutility.