Owner's manual
Error and System Messages
Appendix B
B-5
Message Description
BAD RAMDISC SECTOR CHECKSUM ERROR A RAM disksectorerrorwas detected during the RAMchecksumtestatpower-up. Attemptto
power-up again. If theerrorremains,contactAllen-Bradleycustomersupportservices.
BAD RECORD INPROGRAM This indicatesaseriousproblemwiththeprogram. Attemptto opentheprogram a secondtime.
If retry doesn’twork,youmayhavetodeletetheprogram. Typicallythis errorisnotcaused bya
programmer or operatoraction. Itistypicallycaused by aninternal software errorinthe
program.
BAD STATE/TOKEN COMBINATION (PROGRAM
ERROR)
Whileattemptingtodecode the currentblock,a combinationofcharacters causeda decode
errortooccur. Checkthe characters inthecurrentblockforanillegalcombination.
BATTERY FAILURE The batterythatprovides backup ofthe RAM memory isnotfunctioning;thevoltage maybe low.
The battery may bedead,removed,orpoorlyconnected.
BLK DELETE CHG IGNOREDON PREPARED BLKS A block-delete was activated whilea programwasexecuting. Thischangeis ignored bythe
controlforblocks thathave already beenreadintothe control’sset-up buffer(see block
look-ahead inuser’s manual).
BLOCK LENGTH ERROR Ablockthatexceeds the allowable maximumblock length wasprogrammed.
BLOCK RETRACE ABORTED The block retrace operationbeingperformedhas been canceled. When <CYCLESTART> is
pressed,thecontrol will return the tool along a linearpathback tothestart-pointoftheblock
retraceoperation.
BOOT DIRECTORYISMISSING The updateutility failed to properly create the systembootdirectory. Retrytheupdate. Ifthe
erroroccursagain,contactyourlocalAllen Bradley service.
BOOTSTRAP FAILED TO STAR T The bootstrap codedid notsendthe “ok”signaltothe main processorwithin the specifiedtime.
BOTH AXESIN QPPPLANE NOT PRGMD The secondblockofa currently executingQuickPath Plus two-block setdoes notcontainboth
required axis words inthe currentplane. Bothaxiswordsarerequired to correctlyidentifythe
end-pointofthesecond move.
BOTH LINES AREPARALLEL Bothblocksofa two-block QPP sequence are parallel,and no mathematicalintersection canbe
computed.
BOTH PORTS ARE BUSY Anattemptwasmadetouse or monitorcommunicationports AorBwhen neitherwere
available.
BUSY,REQUEST IGNORED Youhave requestedan operationwhilethecontrolis currentlyexecuting someother higher
priority function. The controlmust firstcomplete the higherprioritytask before yournew task
canbe performed.
C
CALLED 7300PATT ERNNAMEIS BAD The 7300 patternnamethatis called bya partprogramdoesnotexist.
CANCEL/REMOVE OFFSET BEFOREAXISCHANGE You haveattempted to changetheactive tool lengthaxiswhilean length offsetiscurrently
active onthataxis. You must cancel tool lengthoffsetsbefore youare allowed to change the
active tool lengthaxis.
CANNOT (GOTO)TOINSIDE A(DO) A(GOTO)command cannottransferexecution to a block which islocated withina (DO)loop.
CANNOT ACCESS REMOTEVARIABLE Variable nameisinvalid. Checkthefields forCNCname and remotename,andmakesurethey
arein thecorrectformat.
CANNOT ACTIVATE -OPENPROGRAM An attemptwasmadetoactivatea programforexecutionwhen itwas stillopen foran editing
operation. Before itcan be activated forautomatic execution,itisnecessary to press the {EXIT
EDITOR}softkey fromthe editmenu to closea programbeingedited.
CANNOT ACTIVATE RAMPARTITION The RAMdiskhas beencorrupted. Attempttoperforma “REFORMAT ”operation. Ifthisis
unsuccessful,consultAllen-Bradleycustomersupportservices.
CANNOT ASSIGNIN CURRENT MODE Anattemptwasmadeto modifya paramacroparameterthatcannotbe modified whenthecutter
compensationorTTRC feature isactive.
CANNOT CALCULATE -PROMPT PRESENT Anattemptto perform a calculate operation wasmadewhen some otherpromptwas presenton
line2 ofthe CRT. Beforethe controlwillallowa calculationtobe made,itisnecessary to
remove anypromptsfromline2 .