Owner's manual

Chapter 30
Using a 9/Series Dual--processing System
3
0
-
1
7
Figure 30.5
Measuring Interference Checking Areas
Machine
Home
Process 1
Area 1
Area 2
+X
Z and U
XPlus
Area 1
XMinus
Area 1
ZPlus
Area 1
Z Minus
Area 2
Z Minus
Area 1
XPlus
Area 2
XMinus
Area 2
ZPlus
Area 2
Machine
Coordinate
SystemZ ero Point
(Both Processes)
Machine Home
Process 2
Area 1
+U
Process 2
Process 1
UMinus
Area 1
UPlus
Area 1
WPlus
Area 1
WMinus
Area 1
Important: These areas are measured from the machine coordinate zero
point to the extremes of the fixture encompassed by the zone when the
machine is a t home. The machine coordinate system zero point and
machine home are frequently not the same point on the machine. Machine
home is a fixed mechanical position established by the homing sequence
off hardware homing switches. The machine c oordinate system zero point
is established in AMP and referenced from the machine home point (see
chapter 11 for details). Refer to your system installers documentation for
information regarding the location of machine coordinate system zero. For
interference checking t o function properly, both processes must have the
same zero point, but they can have different home locations.