Owner's manual

Chapter 30
Using a 9/Series Dual--processing System
3
0
-
5
Error Messages
The control displays error m essages on the screen for only the currently
active process (except on split-screens). The name of the currently active
process flashes in reverse video if an error occurs in another process.
Change to the a ppropriate process to display the current errors for that
process.
On a split-screen display, the control displays the full error messages for
both processes, regardless of which process is currently active.
The control keeps separate error message logs for each process. The e rror
logs list t he errors in sequential order.
Refer to page NO TAG for more details on error messages.
Single-Digit Feedrates
Both processes share one table of single-digit feedrates. The control looks
to the single-digit feedrate table when it encounters a single-digit F-word
during block execution. The feedrate in this table that corresponds to the
single digit becomes the active feedrate. You cannot define different
single-digit feedrate tables for each process.
The rapids for each individual axis determine the feedrate used for F0.
Your system installer determines the rapid for each axes.
Refer to page 3-23 for information on single-digit feedrates.