Owner's manual

Paramacros
Chapter 28
28-23
Table 28.G
Modal Data Parameters
Parameter Number ModalData Value
#4001 to 4021 These correspondtothedifferentG-codeGroups1-21
(seechapter 10) and showwhatG-codefromgroupis currentlyactive.
4108 CurrentE--wordvalue
4109 CurrentF -- wordvalue
4113 MostrecentlyprogrammedM-code
4114 MostrecentlyprogrammedN--word
4115 CurrentprogramnumberO--word
4119 CurrentS-- wordvalue
4120 CurrentT -- wordvalue
For e xample, if currently programming in G02 mode at a feedrate of 100,
the parameters would be as follows:
G02 is a group 1 G-code, so its value of 02 is set to parameter number
4001.
The feedrate programmed with an F--word gives parameter number 4109 a
value of 100.
#5001 to 5012
Coordinates of End Point
These parameters are read-only. They correspond to the coordinates of the
end point (destination) of a programmed move. These are the coordinates
in the work coordinate system.
5001 Axis 1coordinate position 5007 Axis7 coordinateposition
5002 Axis 2coordinate position 5008 Axis8 coordinateposition
5003 Axis 3coordinate position 5009 Axis9 coordinateposition
5004 Axis 4coordinate position 5010 Axis10 coordinateposition
5005 Axis 5coordinate position 5011 Axis11 coordinate position
5006 Axis 6coordinate position 5012 Axis12 coordinateposition
The system i nstaller determines in AMP the name (or word) that is used to
define the axis.