Coordinate Control
Chapter 13
13-17
When scaling is enabled for a particular axis, the letter ā€œPā€will be
displayed next to the axis name on all axis position display screens. The
following screen shows scaling enabled on all axes.
Figure 13.10
Axis Position Display Screen Showing Scaling Enabled
E-STOP
PROGRAM[ MM ] F 0.000 MMPM
P X 1234.567 S 00
P Y 9876.000 T 0
P Z 2468.000 (ACTIVE PROGRAM NAME)
MEMORY MAN STOP
PRGRAM
MANAGE
OFFSET MACRO
PARAM
QUICK
CHECK
SYSTEM
SUPORT
The scaling magnification data screen lists the currently active scaling
magnification amount, t he current center of scaling, and the default scaling
magnification amount for all axes. The currently active scaling
magnification amount and the current center of scaling for the axes can be
monitored through this screen. The default scaling magnification amount
for the axes can be monitored and/or changed through this screen.
The default scaling magnification values should only be changed when the
control is in a stopped state. If the default values are changed, the new
default values will not become active until the next G14.1 block is
executed.