Owner's manual
Chapter 12
Overtravels and Programmable Zones
12-8
Figure 12.6
Area Defining Programmable Zone 3
Inside or outside border of
Programmable Zone 3
as defined by minimum
and maximum axis values
Z
Y
X
Max X
value
Min X
value
Machine
coordinate
zero
Max Y
value
Min Y
value
Max Z
value
Min Z
value
Unlike the software overtravels, which define the perimeter of an area
from which the c utting tool may not exit, programmable zone 3 can define
either an area that the cutting tool may not exit or an area that the cutting
tool may not enter. This is determined by the current tool location when
programmable zone 3 is made active.
It defines a n area t hat t he cutting tool may not exit if the tool is currently
inside the zone when the z one is activated.
It defines a n area that the cutting tool may not enter if the tool is
currently outside the zone when the zone is activated.