User Manual User Manual

Publication 825-UM002A-EN-P - December 2000
A-14
Instance Attributes
Attribute
ID
Access Rule Name Data Type Value
1Get/Set
only get is
supported for
monitoring
parameters
Parameter Value See Data Type
and Data Size
Attributes
Value Retrieved from
825/CET4
2 Get Link Path Size USINT 06
3 Get Link Path
Segment type/port
Segment address
BYTE
path data
dependent
Path to specific device
object attribute if
applicable
4 Get Descriptor WORD Parameter Dependent:
0000000000ab0cd0
a-Monitoring Parameter
b-Read Only Parameter
c-Scaled Parameter
d-Enumerated String
5 Get Data Type USINT Parameter Dependent
6 Get Data Size USINT Parameter Dependent
7 Get Parameter Name SHORT_
STRING
Parameter Dependent
8 Get Units String SHORT_
STRING
Parameter Dependent
9 Get Help String SHORT_
STRING
Help String
10 Get Minimum Value data type Parameter Dependent
11 Get Maximum Value data type Parameter Dependent
12 Get Default Value data type Parameter Dependent
13 Get Scaling Multiplier UINT 01
14 Get Scaling Divisor UINT 01
15 Get Scaling Base UINT 01
16 Get Scaling Offset INT
can be
negative
00
17 Get Multiplier Link UINT 0
18 Get Divisor Link UINT 0
19 Get Base Link UINT 0
20 Get Offset Link UINT 0
21 Get Decimal Precision USINT Parameter Dependent