Owner manual
F-4 Specifications
7000A-UM151D-EN-P – March 2013 7000 “A” Frame
Dimensions / Weights
Nominal Line
Voltage
Drive Type
VFD
Maximum
Current
Total Width
Approx. Weight
lb (kg)
Millimeters Inches
2400V 60 Hz or
3300V 50 Hz or
4160V 50/60 Hz
Configuration #1 – Direct-to-Drive 140 2100 82.67 4300 (1955)
Configuration #2 – AFE Rectifier with separate isolation
transformer
160 2400 94.49 8300 (3765)
Configuration #3 – AFE Rectifier with Integral isolation
transformer
160 2400 94.49 9800 (4455)
6600V 50/60 Hz
Configuration #1 – Direct-to-Drive 93 2400 94.49 6500 (2955)
Configuration #2 – AFE Rectifier with separate isolation
transformer
105 2800 110.24 10000 (4545)
Configuration #3 – AFE Rectifier with integral isolation
transformer
105 2800 110.24 7500 (3410)
Note: Total Depth = 1000 mm (39.37 in.)
Total Height without fan shroud = 2318 mm (91.25 in.)
Total Height with fan shroud = 2643 mm (104.05 in.)
Nominal Power Ratings
Nominal Line Voltage
VFD Current Range
(Amps)
Nominal HP Range Nominal kW Range
2400V 60 Hz 46 – 160 200 – 700 150 – 522
3300V 50 Hz 46 – 160 250 – 1000 187 – 750
4160V 50/60 Hz 46 – 160 350 – 1250 260 – 933
6600V 50/60 Hz 40 – 105 500 - 1250 400 – 933