FAULT
MESSAGE
FAULT
CODE
DESCRIPTION
RECOMMENDED ACTIONS
Rect HeatSink OT
193
The temperature detection on the Rectifier
Heatsink, connected to Channel A fiber optic
receiver RX7 on FOI-L-A, has exceeded
Rectifier Heatsink Temperature Trip (P315).
Confirm actual temperature in
parameters is not higher than the trip
value If so, investigate the conditions of
the drive (ambient/ loading/ elevation /
ventilation/ filter status /heatsink
clogging)
Check TFB and FOI board for power and
fiber optic integrity
Check the sensor and temperature
offline (ambient) for accuracy
Rect ChannelB OT
194
Not Normally Used - The temperature
detection on a Rectifier Heatsink, connected
to fiber optic receiver RX7 on FOI-L-B, has
exceeded Rectifier Temperature Trip
Channel B (P525).
Rec HS Sensor
201
The drive has detected a missing
temperature sensor connected to the TFB
on the rectifier heatsink. A missing sensor
can result in either a Fiber Optic Loss fault
or a Sensor fault because a missing sensor
can be interpreted as either 0°C or over
100°C, and both are unrealistic values.
Verify sensor is completely seated
properly on TFB.
Measure sensor resistance.
Replace if necessary.
Rec ChB Sensor
202
Not normally used: The drive has detected
a missing temperature sensor connected to
the optional TFB connected to the fiber optic
receiver RX7 on FOI-L-B. A missing sensor
can result in either a Fiber Optic Loss fault
or a Sensor fault because a missing sensor
can be interpreted as either 0°C or over
100°C, and both are unrealistic values.
RNeutral OL
203
The neutral resistor required for Direct-to-
Drive technology has reached an overload
condition. This is determined from
parameters R Neutral (P680), R Neutral
Rating (P681). The current through the
neutral resistor is calculated by measuring
the voltage across the resistor and knowing
the resistance. I Common Mode (P697)
displays that current, and R Neutral OL
(P682) shows the overload accumulator.
The resistor is allowed 500% for 10 seconds
every 5 minutes, and P682 is normalized to
fault whenever the value reaches 1.00.
Verify the resistor ratings
Verify that the drive Voltage Feedback
Splitter board is operating properly
Investigate the possibility of voltage
unbalances on the input or output of the
drive that would create a voltage
differential across the resistor
Contact the factory for further
instructions
SCB Incompat
177
Signal Conditioning Board Incompatible
This is for DTD drive only
The SCB -280 and 380 are used in DTD
drive. The boards have different filter that
cause this fault.
Use -380 board on SCBL and SCBM