Specifications
PanelView
Standard
Network
Connections
Because PanelView
Standard terminals offer
such flexible communication
options, you can optimize
your operator interface
needs to your control or
process architecture. Or, as
your control system needs
change, so can your operator
interface system.
Along with flexible network
connections for runtime
operation, you have multiple
options for uploading and
downloading application
files with PanelBuilder32 –
direct, over the network, or
via a ‘Pass Through’ or
‘Gateway’ connection. And
don’t forget ATA memory
cards for easy file transfers.
Standard Network Connections – Runtime Operation
PanelView Application File Upload/Download
Direct and Network Connections
Network Connection MicroLogix SLC-500, 5/01, 5/02 5/03 5/04 5/05 PLC-5 ControlLogix
Remote I/O n/a 5/02 with 1747-SN with 1747-SN with 1747-SN yes
with 1756-DHRIO**
with 1747-SN
DH+ n/a n/a n/a yes n/a yes
with 1756-DHRIO**
DF1 with AIC+* n/a Ch. 0 Ch. 0 Ch. 0 Ch. 0 n/a
DH-485 (RS485 with AIC+ yes yes with AIC+ with AIC+ n/a n/a
physical connection) to Ch. 0 to Ch. 0
DH-485 (RS232 with AIC+* with AIC+ Ch. 0 Ch. 0 Ch. 0 n/a n/a
physical connection)
DeviceNet
with 1761- NET DNI
5/02 with 1747-SDN
with 1747-SDN with 1747-SDN
with 1747-SDN with 1771-SDN
with 1756-DNB
ControlNet n/a n/a no no no PLC-5C with 1756-CNB***
* For isolation purposes if not on the same power supply.
** Legacy mode. Example: address = N7:0
*** Symbolic (CIP) addressing. Example: address = Tank level
PanelView Type Direct Connection PC (with PanelBuilder32) Network Connection PC (with PanelBuilder32)
to PanelView over Network
DeviceNet 2711-NC13 (via RS-232 printer port) Yes – via PV DeviceNet port
ControlNet 2711-NC13 (via RS-232 printer port) Yes – via PV ControlNet port
Data Highway Plus 2711-NC13 (via RS-232 printer port) Yes – via PV DH+ port
Remote I/O 2711-NC13 (via RS-232 printer port) N/A – use a Pass-Through connection
DH-485 (RS-485 port) 1747-PIC* or AIC+ module Yes – via PV DH-485 port
DH-485 (RS-232 port) 2711-NC13 (via RS-232/DH485 port) or Yes – via PV RS-232 (DH-485) port
PV 300 Micro: 2711-CBL-PM05 or -PM10 (select terminals only)
DF1 2711-NC13 (via RS-232 port) or N/A – use a Pass-Through connection
2711-NC13 (via RS-232 printer port –
select terminals only)
Profibus 2711-NC13 (via RS-232 printer port) N/A
Modbus 2711-NC13 (via RS-232 printer port) N/A
* When connecting a personal computer to a PanelView terminal, using a PIC without a controller connected, you need a power supply (1747-NP1)
PanelView Application File Upload/Download
Pass-Through & Gateway Connections
PC Network (PC to Controller) Controller*/Gateway PanelView Network (Controller to PanelView)
Ethernet ControlLogix/Gateway ControlNet, DeviceNet, RI/O, DH+
PLC-5 DeviceNet, RI/O
SLC 5/05 DeviceNet, RI/O, DH-485, DF1
ControlNet ControlLogix/Gateway DeviceNet, RI/O, DH+
PLC-5 DeviceNet, RI/O
DH+ PLC-5 DeviceNet, RI/O
SLC 5/04 DeviceNet, RI/O, DH-485, DF1
DH-485 SLC 5/03, 5/04 , 5/05 DeviceNet, RI/O
SLC 5/04 DH+
DF1 ControlLogix/Gateway ControlNet, DeviceNet, RI/O
SLC 5/03, 5/04, 5/05 DeviceNet, RI/O
SLC 5/04 DH+
* The controller must support PC network as well as PanelView network. Consult controller manual for details