Installation Instructions Industrial Performance Monitors Catalog Numbers 6186M-12PN, 6186M-12PT, 6186M-15PN, 6186M-15PT, 6186M-15PNSS, 6186M-15PTSS, 6186M-17PN, 6186M-17PT, 6186M-17PNSS, 6186M-17PTSS, 6186M-19PN, 6186M-19PT, 6186M-19PNSS, 6186M-19PTSS Topic Page Important User Information 2 About This Publication 3 Summary of Changes 3 Hazardous Locations 4 Control Drawing - Class I Division 2 and Zone 2 (USB Port-Type A) 6 Control Drawing - Class I Division 2 and Zone 2 (USB Port-Type B) 7
Industrial Performance Monitors Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices.
Industrial Performance Monitors 3 About This Publication This document provides instructions on how to install your monitor. Monitors can be installed in a panel, rack, bench, or tabletop and are VESA mount-ready. This document does not provide information on monitor configuration or setup. Summary of Changes This manual contains new and updated information. Changes throughout this revision are marked by change bars, as shown to the right of this paragraph.
Industrial Performance Monitors Hazardous Locations This equipment is suitable for hazardous locations specified on the product nameplate: • Class I, Division 2 Groups A, B, C, D • Non-hazardous locations The following statement applies to use in hazardous locations. WARNING: Explosion Hazard • Substitution of any components may impair suitability for hazardous locations.
Industrial Performance Monitors 5 Environnements dangereux Cet équipement peut être utilisé dans les environnements suivants : • • • • Classe I, Division 2, Groupes A, B, C et D . Classe II, Division 2, Groupes F et G . Classe III, Division 1 . non dangereux. La mise en garde suivante s’applique à une utilisation en environnement dangereux. Danger d'explosion La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement dangereux.
Industrial Performance Monitors Control Drawing - Class I Division 2 and Zone 2 (USB Port-Type A) The following control drawing is provided to comply with the National Electrical Code, Article 500 pertaining to Class I, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC.
Industrial Performance Monitors 7 Control Drawing - Class I Division 2 and Zone 2 (USB Port-Type B) The following control drawing is provided to comply with the National Electrical Code, Article 500 pertaining to Class I, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC.
Industrial Performance Monitors Application Information The circuit parameters of associated field-wired apparatus for use in hazardous locations shall be coordinated with the host product such that their combination remains nonincendive. The Industrial Performance monitors and USB peripheral devices shall be treated in this manner. The circuit parameters of the Industrial Performance monitors’ USB ports are given in the Industrial Performance Monitors USB Port Circuit Parameters table.
Industrial Performance Monitors 9 Environment and Enclosure Information Review the information on enclosures and environments before installing the product. ATTENTION: Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 m (6561 ft) without derating.
Industrial Performance Monitors Parts List The monitors are shipped with these items: • • • • • • • • • Mounting clips and cutout template AC power supply and applicable power cord HD-15 analog video cable DVI cable Touch screen serial cable (only for monitors with touch screen display) USB cable Cable retention tie wraps Installation Instructions Accessories CD (contains the installation files for the monitor drivers and the ScreenSet monitor setup utility) Required Tools These tools are required fo
Industrial Performance Monitors 11 • The surrounding air temperature must not exceed the maximum operating temperature. Consider heat produced by other devices in the enclosure. You may need a user-supplied fan, heat exchanger, or air conditioner to meet this condition. TIP Hot air rises. The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure, especially if air is not circulating. IMPORTANT The product can operate at a range of extremes.
Industrial Performance Monitors Installing the Monitor There are various ways to install the monitors. • Panel mount • Rack mount • Bench or tabletop mount Review each mounting type and product dimensions before installation. Panel Mounting Monitors install directly into a panel with mounting clips. The number of clips vary by model. Monitor Model Number of Clips 1200M, 1500M, and 1700M aluminum bezel 10 1700M stainless steel bezel 12 1900M 14 Cat. No.
Industrial Performance Monitors 13 Mounting Guidelines Observe these guidelines when installing the monitor in a panel: • Confirm that there is adequate space behind the panel. – Allow a minimum of 51 mm (2.0 in.) around the back, sides, and bottom, and 77 mm (3.0 in.) on the top for ventilation. – A cabinet with a minimum depth of 112 mm (4.4 in.) is sufficient. • Cut supporting panels to specifications before installation.
Industrial Performance Monitors Mount the Monitor in a Panel Follow these directions to mount the monitor in a panel. 1. Cut the panel opening by using the appropriate cutout dimensions. 2. Attach cables to the monitor before installing the monitor if rear access to the monitor will be limited after installation. See “Monitor Connections” on page 26 for where to attach cables. 3. Verify the sealing gasket is properly positioned on the monitor. This gasket forms a compression-type seal.
Industrial Performance Monitors 15 Rack Mounting You can install the 1200M, 1500M, and 1700M monitors directly into an EIA-rack cabinet by using the appropriate rack adapters. Cat. No. Description 6189V-MRA12 Rack adapter for 1200M monitor 6189V-MRA15 Rack adapter for 1500M monitor 6189V-MRA17 Rack adapter for 1700M monitor Mounting Guidelines Observe these guidelines when installing the monitor in an EIA-rack cabinet: • The cabinet height must accommodate the monitor’s panel height.
Industrial Performance Monitors Mount the Monitor in a Rack Follow these directions to mount the monitor. 1. Place the 1200M, 1500M, or 1700M monitor in the rack adapter ( ) and attach it to the rack adapter with the mounting clips provided ( ). 2. Secure the adapter to the cabinet by installing screws through the holes in the adapter, and into the mounting rails ( ).
Industrial Performance Monitors 17 Bench or Tabletop Mounting Use the optional bench/tabletop adapter for monitors, catalog number 6189V-MBA, to mount your monitor on a bench or tabletop arm. Mounting Guidelines Observe these guidelines when installing the monitor on an arm: • The mounting surface and the mounting arm must be strong enough to support both the monitor and the mounting hardware. • The interface between the arm and the monitor must meet VESA FPMPMI 100 mm (3.94 in.) standards.
Industrial Performance Monitors DIN Rail Mounting of the AC Power Adapter You can mount the AC power adapter on a DIN rail by using the DIN rail mounting accessory, catalog number 6189V-MPSDIN. Follow these steps to mount the AC power adapter to a DIN rail. 1. Attach the DIN rail bracket to the bottom of the AC power adapter ( ). 2. Secure the DIN rail bracket by using four of the provided M4 x 6 mm screws ( ). 3. Torque the screws to 0.882 N•m (7.811 lb•in). 4.
Industrial Performance Monitors 19 Product Dimensions The product dimensions for the monitors are in mm (in.). 1200M Monitor 315 (12.40) 26.6 (1.05) 291 (11.46) 260 (10.24) 197 (7.76) 235 (9.25) 5.5 (0.22) 340 (13.39) 12 (0.47) 60.5 (2.
Industrial Performance Monitors 1500M Aluminum Bezel 383.6 (15.10) 296 (11.65) 28 (1.10) 60.55 (2.38) 199.50 (7.85) 308.98 (12.16) 282.6 (11.13) 5 (0.20) 409.98 (16.14) 50.80 (2.
Industrial Performance Monitors 21 1500M Stainless Steel Bezel 383.6 (15.10) 296 (11.65) 26 (1.04) 60.55 (2.38) 199.50 (7.85) 309 (12.17) 282.6 (11.13) 4.3 (0.17) 410 (16.14) 50.80 (2.
Industrial Performance Monitors 1700M Monitor - Aluminum Bezel 421.5 (16.59) 296 (11.65) 28 (1.10) 60.55 (2.38) 5 (0.20) 327.6 (12.90) 199.50 (7.85) 356 (14.03) 451.98 (17.79) 73.30 (2.
Industrial Performance Monitors 23 1700M Monitor - Stainless Steel Bezel 421 (16.57) 296 (11.65) 27.8 (1.09) 60.15 (2.37) 4.3 (0.17) 326.5 (12.85) 199 (7.85) 356 (14.02) 452 (17.80) 72.75 (2.
Industrial Performance Monitors 1900M Monitor - Aluminum Bezel 446.6 (17.58) 325 (12.80) 31.5 (1.24) 63.9 (2.52) 360.5 (14.19) 399.3 (15.72) 242 (9.53) 4.2 (0.17) 482.6 (19.0) 75.25 (2.
Industrial Performance Monitors 25 1900M Monitor - Stainless Steel Bezel 446.6 (17.58) 325 (12.80) 31.5 (1.24) 64.0 (2.52) 4.3 (0.17) 360.5 (14.19) 242 (9.53) 399.3 (15.72) 482.6 (19.0) 75.25 (2.
Industrial Performance Monitors Monitor Connections Use the connectors on the rear bottom side of the monitor to connect to a video host and a power source.
Industrial Performance Monitors 27 Connect to an Analog Video Source All monitors support analog video. Your monitor is shipped with a high-quality analog video cable. Use this video cable to connect a computer to the monitor. Cat. No. Description 6189V-VGACBL2 Analog video cable, 1.9 m (6.3 ft) 6189V-PCIDVI Dual Analog/Digital Video Card, PCI Follow these steps to connect the monitor to an analog video source. 1. Connect one end of the 1.
Industrial Performance Monitors Connect the Optional Touch Screen Interface An optional touch screen provides a high-resolution touch input system. The driver software included with the monitor allows the touch screen to function with many Microsoft Windows-based industrial applications such as a pointing device or mouse. A touch screen interface to the computer can be configured using either the serial RS-232 connection or USB connection.
Industrial Performance Monitors 29 Installing the Touch Screen Driver Software 1. Before installing the touch screen driver software, check the following for the interface you are using. 2. RS-232 Interface: Verify that the supplied RS-232 cable is properly installed between RS-232 input connector on the monitor and the host’s COM port. 3. USB interface: Verify that the USB cable is properly installed between the USB input connector on the monitor and a USB port on the host computer. 4.
Industrial Performance Monitors Power Source Connection The monitor connects to either a 100…240V AC or a 9V…36V DC power source, but should not be connected to AC and DC voltage at the same time. Connect AC Power With the AC power adapter, the monitor can use a single-phase AC power supply, providing 100…240V AC at 47…63 Hz. Only use the AC adapter supplied with the monitor. IMPORTANT Do not use the AC adapter and external DC at the same time. Power must be available at a grounded outlet nearby.
Industrial Performance Monitors 31 3. Hard wire the AC power using the provided AC power cord ( ). Make sure that the power cord is firmly secured to the AC power adapter by the metal cage already attached to the adapter. 4. Restore AC power. Connect DC Power The monitors connect to a DC power source using a DC input terminal block. The DC power option supports operation from either a safety-extra low (SELV) or protective extra-low voltage (PELV) power source.
Industrial Performance Monitors Secure the Cables All cables should be secured to each other or a fixed object after leaving the monitor by using the supplied cable ties. Securing the cables provides strain relief and avoids loose, hanging cables. It is particularly important in shock and vibration environments to reduce movement of the cables. Functional Ground Screw The pre-installed functional ground screw is not required for safety or regulatory compliance.
Industrial Performance Monitors 33 Specifications Industrial Monitors - 1200M, 1500M, 1700M, 1900M Attribute Display Electrical Mechanical Specification 1500M models Type Color active matrix TFT Touch screen description Resistive antiglare 1700M models 1900M models Size (diagonal), approx. 307 mm (12.1 in.) 381 mm (15.0 in.) 432 mm (17.0 in.) 483 mm (19.0 in.) Display area (W x H), approx. 246 x 185 mm (9.7 x 7.3 in.) 304 x 228 mm (12 x 9 in.) 338 x 270 mm (13.3 x 10.7 in.
Industrial Performance Monitors Certifications 1200M, 1500M, 1700M, and 1900M models UL Listed Class I, Division 2, per ISA 12.12.01 (when marked on the nameplate) cUL Listed Class I, Division 2, per CSA No. 213 (when marked on the nameplate) CE marked for all applicable directives RoHS compliant C-Tick China RoHS Turkey RoHS Additional Resources For additional information on the industrial monitors, refer to the Industrial Performance Monitors User manual, publication 6186M-UM002.
Industrial Performance Monitors 35 Notes: Rockwell Automation Publication 6186M-IN002C-EN-P - December 2011
Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.