Industrial 20" CRT Monitor (Bulletin 6157) Installation and User Manual
Table of Contents 7DEOH RRII &RQWH &RQWHQQWV Industrial 20" CRT Monitor.............................................. Description........................................................................... Package Contents ................................................................. Installing the 6157 Industrial Monitor................................... Panel Mounting.................................................................... Connecting the 6157 Industrial Monitor........................
Industrial 20" CRT Monitor 3 ,QGXVWULDO &57 0RQLW 0RQLWR RU Description The Bulletin 6157 20" Industrial CRT Monitor is a general purpose monitor suitable for a wide range of industrial computing applications.
Industrial 20" CRT Monitor Available Options The following options are available to the 6157 Industrial Monitor: • Video interface options (HD-15, 5 BNC) • Touchscreen options (resistive, capacitive) • Touchscreen cable options • Video cable options • Power cord options • Magnetic shield options Package Contents The monitor shipping carton contains the following items: • Monitor • Package of mounting hardware • AC power cord (optional) • Video cable (optional) • This user manual A 6157 Industrial Moni
Industrial 20" CRT Monitor Installing the 6157 Industrial Monitor 5 This section describes how to install the monitor.
Industrial 20" CRT Monitor • Determine the minimum and maximum ambient humidity for the monitor by consulting the specification sheets at the back of this manual. Ensure that the humidity of the ambient air will not exceed these limits. In very dry environments, static charges build up very readily. Proper grounding of the equipment through the AC power cord can help reduce the likelihood of static discharges, which may cause shocks and damage electronic components.
Industrial 20" CRT Monitor 7 Panel Mounting Guidelines Observe the following precautions before installing the unit in a panel: • Confirm that there is adequate space behind the panel. Remember to allow extra space (3 in. (76.2 mm) behind and 1 in. (25.4 mm) below and on each side) for air circulation. • Confirm that the cabinet is deep enough to accommodate the monitor's depth while providing rear clearance for airflow. A cabinet with depth of 23.11 in. (587 mm) is sufficient.
Industrial 20" CRT Monitor Mounting the 6157 Industrial Monitor in a Rack Due to the front panel size and stud pattern, the 6157 Industrial Monitor can be installed in an EIA 19” 9U panel standard rack. Refer to the following figure: Figure 2 Generic Rack Mounting Diagram Important: If you install the 6157 Industrial Monitor in a rack, you must ensure that the rack can support the weight of the monitor. You might need to install a support or shelf under the rear of the monitor to support the weight.
Industrial 20" CRT Monitor 9 Dimensions This section provides diagrams you need to follow to install the unit. Figure 3 6157 Industrial Monitor Dimensions Publication 6157-5.
Industrial 20" CRT Monitor Panel Mounting Procedure 1. Confirm that the shipping carton contains a package of 20 10-32 lock nuts and 20 flat washers. You will need 18 nuts and washers for installation. 2. Refer to the physical dimension drawing (Figure 3) and confirm that there is adequate space behind the panel. Remember to allow extra space for circulation and cabling. 3. Refer to the panel cutout drawing below for dimensions of the panel cutout and mounting hole locations. Cut and drill the panel.
Industrial 20" CRT Monitor 11 4. Carefully remove the monitor from its packaging. Avoid damaging the monitor gasket. Tip: It will be easier to install the monitor if you support it with a shelf or other support adjusted to the appropriate height. 5. Insert the monitor in the panel cutout from the front. Do not damage the threaded mounting studs as you position the monitor. 6. Secure the unit with the lock nuts and washers provided. Tighten evenly to 24 inch-pounds of torque.
Industrial 20" CRT Monitor Connecting the 6157 Industrial Monitor The rear panel of the 6157 Industrial Monitor has connectors for attaching cables to accomplish the following: • Connecting to a host video source (HD-15 VGA or BNC connectors) • Connecting to a host touchscreen control port (DB-9 connector) (optional) • Connecting to AC power Note: Some connectors on your monitor may differ from the following figure.
Industrial 20" CRT Monitor 13 Connecting the Video Source The video connection to the host is made through a HD-15 (female) connector or through BNC input connectors. To establish a signal using the HD-15 connector: Note: For more information on using an HD-15 video cable to connect to the host computer, refer to Appendix B (Page 28). 1. Obtain a shielded, properly terminated video cable of length as short as possible.
Industrial 20" CRT Monitor Connecting the Configuration Port The 6157 Industrial Monitor is equipped for remote control by the host computer. You can use the serial configuration port to provide bidirectional communication between the monitor and the host computer. The host computer can send commands to the monitor requesting information about the monitor’s status or to adjust monitor operating conditions. Note: Please contact Technical Support for more information on using the configuration port.
Industrial 20" CRT Monitor 15 To connect the touchscreen: 1. For units with the touchscreen option, make sure you have one of the optional serial cables. 2. Connect one end of the touchscreen serial cable to the T/S port connector on the rear of the monitor. 3. Connect the other end to any serial communications port on the host computer. 4. Tighten the captive screws on the cable connector to secure it.
Industrial 20" CRT Monitor Operating the 6157 Industrial Monitor This section describes how to operate the 6157 Industrial Monitor. Controls The following is a summary of the controls and indicators on the membrane keypad on the 6157 Industrial Monitor: Figure 6 Monitor-Resident Controls Note: The number of controls supported by the monitor may vary depending on the monitor type or customer-specified options.
Industrial 20" CRT Monitor 17 Manual Degauss The monitor is equipped with an automatic degaussing system to remove residual magnetism from the CRT’s shadow mask at power-up. Degaussing helps keep the screen free of any color impurities which might otherwise result from magnetism picked up by the shadow mask from the earth’s magnetic field when the monitor is moved. In addition, a degauss push button is provided on the control panel.
Industrial 20" CRT Monitor 4. Use the left arrow button to lower the brightness until the dark gray colors change back to black. This is the optimal brightness setting given the current lighting conditions 5. Press the Select Mode button until the status LED indicator below the Contrast icon is lit. 6. Use the left and right arrow buttons to change the value for the contrast control to achieve the appropriate level of intensity in the image.
Industrial 20" CRT Monitor 19 To change raster rotation: 1. Press the Select Mode button until the status LED indicator below the raster rotation icon is lit. 2. Use the left and right arrow buttons to adjust the rotation. Important: The raster rotation control cannot correct for the effects of external AC fields such as those produced by large motors, generators and transformers. Such effects often take the form of display jitter.
Industrial 20" CRT Monitor Routine Maintenance Cleaning Occasionally clean the display panel and cabinet with a soft cloth dampened (not soaked) with a mild (non-abrasive) glass cleaner. Keep turning a fresh side of the cloth toward the screen surface to avoid scratching it with accumulated grit. Note: The solvent should be applied only to the cloth, and not directly on the monitor screen. Do not use paper products as they may scratch the surface.
Industrial 20" CRT Monitor 21 Fuse Replacement The Bulletin 6157 Industrial Monitor is equipped with two AC line fuses housed in the IEC connector (2.5A 250V). To access the fuses, you must remove the rear cover of the unit. ATTENTION: Fuse replacement requires work in areas that can present dangerous voltages. Always disconnect the AC power cord and wait one minute before attempting fuse replacement. Replace the rear cover before restoring power to the monitor. To replace the fuses: 1.
Industrial 20" CRT Monitor 4. Remove each fuse by inserting the tip of a small flat-bladed screwdriver between the fuse clip and the metal end cap of the fuse and gently prying the fuse out of its clip. 5. Replace each fuse as required with a 5ST Slo-Blo type fuse rated at 2.5A, 250VAC. 6. After replacing each fuse in its clip holder, reinstall the plastic cover over the fuses, reinstall the rear panel of the monitor, and reconnect the AC power cord.
Industrial 20" CRT Monitor Troubleshooting 23 You can refer to this table to help identify the cause and offer a solution to a problem. This table lists typical problems you may encounter. Table A Troubleshooting Table Symptom None of the status LEDs are lit. Possible Problem Action Power cord not connected. Open power switch. Reconnect power cord at monitor and at AC outlet. Close power switch. No power available at AC outlet. Test AC outlet by plugging in a lamp or other known good device.
Industrial 20" CRT Monitor Symptom Display is present and stable, but missing some color(s) Possible Problem Video cable problem. Action Check for proper video cable installation. If using BNC inputs, test monitor as follows. Disconnect signal cable(s) corresponding to the missing color(s). Disconnect signal cable corresponding to a displayed color and connect it to the input(s) corresponding to the missing color(s).
Industrial 20" CRT Monitor 25 $ SSHQGL[ $ 7RX RXF FKVF KVFU U HHQ 6 6H HULDO ,QWHUIDFH Description All touch controllers are configured by default to provide serial communications at 9600 baud, 8 data bits, 1 stop bit, no parity. For Allen-Bradley monitors equipped with touchscreens, a serial communications cable is required. A suitable cable can be obtained from Rockwell Automation or you can create one.
Industrial 20" CRT Monitor Interconnecting wiring to the host serial port connection is shown in the following table.
Industrial 20" CRT Monitor Note: 27 Before installation, you may want to check the touchscreen manufacturer’s site on the World Wide Web for the latest software drivers. Enter these addresses in your Internet browser: • www.elotouch.com for resistive touchscreens • www.microtouch.com for capacitive touchscreens. Performing a Calibration After installing the driver software, follow the instructions in the touchscreen documentation.
Industrial 20" CRT Monitor $ SSHQGL[ % 9 LGHR & &D DEOHV You can use two types of video cable connectors to connect the 6157 Industrial Monitor to the host computer: • HD-15 connectors • BNC connectors. HD-15 Connectors The HD-15 video cable you use with this monitor is equipped with a conventional HD-15 connector at each end. Note: The following figure is the view looking into the pin end of the male connector or solder term end of the female connector.
Industrial 20" CRT Monitor 29 Table C Standard HD-15 Video Cable Monitor HD-15 (Female) BNC Connectors Signal Description Host HD-15 (Male) 1 Red Video 1 2 Green Video 2 3 Blue Video 3 4 Return 4 5 Not Used 5 6 Red Video Ground 6 7 Green Video Ground 7 8 Blue Video Ground 8 9 +5V (Optional) 9 10 Sync Ground 10 11 Return 11 12 Bi-Directional Data 12 13 Horizontal Sync 13 14 Vertical Sync (VCLK) 14 15 Data Clock (SCL) 15 The BNC cables you use with this monit
Industrial 20" CRT Monitor The following table describes the signal types you can use with these BNC connectors: Table D BNC Signal Types BNC Signal Type Description R G B Sync-on-Green Use the three video connectors. Horizontal and vertical syncs are supplied on the green video line. X X X Separate Composite Sync Use the three video connectors plus the horizontal sync/composite sync input.
Industrial 20" CRT Monitor 31 Specifications Display CRT Type 20” diagonal, 0.28mm dot pitch SP phosphor, 51.5% glass, AGRAS coating, low thermal exapansion shadow mask, DAF electron guns, tension-band implosion protected Degaussing Manual and automatic Nominal Display Area (4:3 aspect) Horizontal 14.7in. (374mm) (4:3 aspect) Vertical 11.0in. (280mm) (5:4 aspect) Horizontal 13.8in. (350mm) (5:4 aspect) Vertical 11.0in.
Industrial 20" CRT Monitor Video (cont.) Sync Input Signals Separate Horizontal and Vertical Sync Control, TTL signal levels Sync on green (0.286V below ref.
IBM is a registered trademark of International Business Machines Corporation. VGA is a trademark of International Business Machines Corporation. PC AT is a trademark of International Business Machines Corporation. Microsoft is a registered trademark of Microsoft Corporation. Microsoft Windows is a trademark of Microsoft Corporation.