Manual
Industrial 14” CRT Monitors 23
Publication 6156-2.0
Environmental
Operating Temperature
0
°
C to +50
°
C
Storage Temperature
–30
°
C to +70
°
C
Relative Humidity 5% to 95% (non–condensing)
Operating Shock 15g (1/2 sine, 11 msec duration)
Non–operating Shock 30g (1/2 sine, 11 msec duration)
Operating Vibration 0.01 in. p-p 5-17 Hz sine, 1.5g peak, 17-640 Hz sine
Non–operating Vibration 0.2 in. p-p 5-16 Hz sine, 2.5g peak, 16-640 Hz sine
Physical
Faceplate Overall Height 12.2” (310mm)
Faceplate Overall Width 19.0” (483mm)
Overall Depth (from rear
surface of front panel to back)
16.3” (414mm)
Net Weight approx. 50lbs (23kg)
Standards Compliance
RF Emissions FCC Class A Certified
Safety (Electrical Shock, Fire) EN60950, UL / C-UL 1950 recognized component
CE Compliance Directives 89/336/EEC, 73/23/EEC
Enclosure UL / C-UL 508 Listed
NEMA 4, 12, 13 (when properly installed in panel)
X–ray Emissions DHHS CFR 21.1020 compliant
Specifications (Continued)