Manual
Chapter 3
Installation
3-6
The factory sets the switches for memory address C000(hex) for an IBM
PC AT or other machine with a 16-bit bus. If you’re running on a PC XT
or another 8-bit bus machine, or if you want to configure the scanner at an
address other than C000(hex), you’ll have to change the switches.
First set switches 7 through 10 to all closed for a PC AT or similar, all open
for a PC XT or similar. The factory setting is all closed, for a PC AT or
other machine with a 16-bit bus.
Next set switches 1 through 6 for the memory address you selected.
Table 3.C shows the correct setting of switches 1 through 6, in that order,
for every hex address below F000, where
O is an open switch and c is a
closed switch:
Table 3.C
Dip
Switch Settings for Memory Address (Switches 1 through 6)
Hex
Address
Switch
Setting
Hex
Address
Switch
Setting
Hex
Address
Switch
Setting
0400 Occ ccc 5000 ccO cOc A000 ccc OcO
0800 cOc ccc 5400 OcO cOc A400 Occ OcO
0C00 OOc ccc 5800 cOO cOc A800 cOc OcO
1000 ccO ccc 5C00 OOO cOc AC00 OOc OcO
1400 OcO ccc 6000 ccc OOc B000 ccO OcO
1800 cOO ccc 6400 Occ OOc B400 OcO OcO
1C00 OOO ccc 6800 cOc OOc B800 cOO OcO
2000 ccc Occ 6C00 OOc OOc BC00 OOO OcO
2400 Occ Occ 7000 ccO OOc C000 ccc cOO
2800 cOc Occ 7400 OcO OOc C400 Occ cOO
2C00 OOc Occ 7800 cOO OOc C800
1
cOc cOO
3000 ccO Occ 7C00 OOO OOc CC00 OOc cOO
3400 OcO Occ 8000 ccc ccO D000 ccO cOO
3800 cOO Occ 8400 Occ ccO D400 OcO cOO
3C00 OOO Occ 8800 cOc ccO D800
2
cOO cOO
4000 ccc cOc 8C00 OOc ccO DC00 OOO cOO
4400 Occ cOc 9000 ccO ccO E000 ccc OOO
4800 cOc cOc 9400 OcO ccO E400 Occ OOO
4C00 OOc cOc 9800 cOO ccO E800 cOc OOO
9C00 OOO ccO EC00 OOc OOO
1
Not available for the IBM PC XT
2