Table 4 IEC Short Circuit Ratings per EN60947-4-1
MCS-E3 Cat. No. Prospective S.C.
current, Ir (A)
Conditional S.C.
current, Iq (A)
Max. voltage (V)
193-EC_B, 592-EC_T 1,000
193-EC_D, 592-EC_C 3,000
193-EC_E, 592-EC_D 5,000
193-EC_F
10,000
193-EC_G
18,000
193-EC_H
30,000
193-EC_Z
1,000
Fuse Coordination
Contactor Cat. No. Max. starter FLC
(A)
Prospective S.C.
current, Ir (A)
Conditional S.C.
current, Iq (A)
Max. voltage
(V)
Type I with
Class J fuse (A)
Type II with
Class J fuse (A)
_
B
100-C09 9 20 15
_
B
100-C12 12 20 20
_
B
100-C16 16 30 30
_
B
100-C23 23 40 40
_D 100-C30 30 50 50
_D 100-C37 37 50 50
_D 100-C43 43 70 70
_E 100-C60 60 80 80
_E 100-C72 72 100 100
_E 100-C85 85
5,000
150 150
FF, ZZ 100-D95 95 200 200
FF, ZZ 100-D110 110 200 200
FF, ZZ 100-D140 140 250 250
GF, ZZ 100-D180 180 300 300
GG, ZZ 100-D210 210 400 400
GG, ZZ 100-D250 250 400 400
GG, ZZ 100-D300 300 500 500
HG, ZZ 100-D210 210 400 400
HG, ZZ 100-D250 250 400 400
HG, ZZ 100-D300 300 500 500
JG, ZZ 100-D300 300 500 500
JG, ZZ 100-D420 420 600 600
Contactor Size
Max. starter FLC
(A)
Prospective S.C.
current, Ir (A)
Conditional S.C.
current, Iq (A)
Max. voltage
(V)
Type I with
Class J fuse (A)
Type II with
Class J fuse (A)
00 9 1,000 20 20
0, 1 18, 27
3,000
30 30
245
3,000
60 60
390
5,000
200 200
592-EC
_
T
592-EC
_
C
592-EC
_
C
592-EC
_
D
10,000
3,000
100,000 600
100,000 600
MCS-E3 Cat. No.
100,000 690
MCS-E3 Cat. No.
193-EC1
193-EC2
193-EC3
193-EC4
193-EC5
1,000
Table 6 Type 1 and Type II Fuse Coordination with NEMA Contactors
Table 5 IEC Type 1 and Type II Fuse Coordination with Bul. 100-C and 100-D contactors per EN60947-4-1
PN-17757
DIR 10000010791 (Version 03)