3Ć3
Table 3.1 - Port Locations and DIP Switch Settings (Continued)
0x0638
ON OFF OFF ON ON ON
0x0640 ON OFF ON OFF OFF OFF
0x0648 ON OFF ON OFF OFF ON
0x0650 ON OFF ON OFF ON OFF
0x0658 ON OFF ON OFF ON ON
0x0660 ON OFF ON ON OFF OFF
0x0668 ON OFF ON ON OFF ON
0x0670 ON OFF ON ON ON OFF
0x0678 ON OFF ON ON ON ON
0x0680 ON ON OFF OFF OFF OFF
0x0688 ON ON OFF OFF OFF ON
0x0690 ON ON OFF OFF ON OFF
0x0698 ON ON OFF OFF ON ON
0x06A0 ON ON OFF ON OFF OFF
0x06A8 ON ON OFF ON OFF ON
0x06B0 ON ON OFF ON ON OFF
0x06B8 ON ON OFF ON ON ON
0x06C0 ON ON ON OFF OFF OFF
0x06C8 ON ON ON OFF OFF ON
0x06D0 ON ON ON OFF ON OFF
0x06D8 ON ON ON OFF ON ON
0x06E0 ON ON ON ON OFF OFF
0x06E8 ON ON ON ON OFF ON
0x06F0 ON ON ON ON ON OFF
0x06F8 ON ON ON ON ON ON
Note: These port locations are the only I/O addresses recognized by
the AutoMax Programming Executive software.
If you are not using the PC Link module with the AutoMax
Programming Executive software, any of the addresses listed in Table
3.1 are possible, although other equipment in the personal computer
may conflict with the address chosen. Keep in mind that the I/O
space required is 8 bytes, so a setting of 250 actually uses ports
250Ć257.