Owner's manual
Chapter 5
Using the RS–232 Ports
5–12
Use this command to read the results of the last inspection. Refer to
Appendix B for a description of the results blocks. Use the following
commands:
>RRx,TSno,d [CR]
Where: x = Number of times command is repeated.
n = Toolset number TS1, TS2, or S
(CVIM module status)
o = RL (specifies Reference Line)
RW (specifies Reference Window)
G (specifies Gage)
W (specifies Window)
LP (specifies Light Probe)
d = Gage, Window, Reference Line, or
Reference Window number.
>RRx, TS1 [CR] Reads discrete bit results for toolset 1.
x = Number of times command is repeated.
>RRx,TS2 [CR] Reads discrete bit first results for toolset 2.
x = Number of times command is repeated.
>RRx,TS1RB,d [CR] Reads results block(s) for toolset 1
x = Number of times command is repeated.
d = Block number.
>RRx,TS2RB,d [CR] Reads results block(s) for toolset 2.
x = Number of times command is repeated.
d = Block number.
>RRx, S [CR] Reads CVIM module status.
Read Inspection Results