Owner's manual

Appendix D
Configuration Data
D15
Table D.11 shows the function of each word in the polygon configuration
blocks.
Table D.11
Polygon Configuration Blocks #128135
Remote I/O
& RS232
Word #*
Bit # Definition Usage Notes
1 015 Block Transfer Signature
236 015 Reserved
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
The template blocks begin at block #136. The number of template blocks
stored in memory is variable. Word 1, bits 815 (third byte sent using
RS232) of the first template block indicate the total number of template
blocks in the configuration. You must always upload or download all of the
template blocks as a unit. You cannot archive only a part of the template
blocks. When uploading templates from the CVIM module, the program
should read the first template block and check word 1, bits 815 (third byte
sent using RS232) to determine the number of template blocks to follow.
The number of blocks remaining is then 1 less than the total number of
template blocks. When downloading templates to the CVIM module, the
program must send all template blocks. Bits 815 of word 1 determine the
number of blocks to send.
Configuration Blocks 128135
Template Blocks 136