Owner's manual

Appendix D
Configuration Data
D7
Table D.4
Configuration Blocks #79 Reference Windows 13 (Toolset 1)
Remote I/O
& RS232
Word #*
Bit # Definition Usage Notes
20 015 Feature 2 Search Window Height
2124 015 Reserved
25 07 Reserved
25 815 Feature 2 Score 0 = Minimum Value
255 = Maximum Value
26 015 Feature 3 Search Window X
Location
Relative to the upper left corner.
27 015 Feature 3 Search Window Y
Location
Relative to the upper left corner.
28 015 Feature 3 Search Window Width
29 015 Feature 3 Search Window Height
3033 015 Reserved
34 07 Reserved
3435 815 Feature 3 Score 0 = Minimum Value
255 = Maximum Value
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Table D.5 shows the function of each word in the gage 132 (Toolset 1)
configuration blocks.
Table D.5
Configuration Blocks #1041 Gages 132 (Toolset 1)
Remote I/O
& RS232
Word #*
Bit # Definition Usage Notes
0 015 Block Transfer Signature
1 0 Enable 0 = Disabled
1 = Enabled
1 115 Reserved
23 015 Reserved
4 07 Low Threshold/Gray Scale Factor 0 63
0 197
If binary operation, value is used as the
threshold. If gray scale operation, value is
scale factor.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Configuration Blocks 10 41