Owner's manual

Appendix D
Configuration Data
D6
Table D.3
Configuration Blocks #46 Reference Lines 13 (Toolset 1) continued
Remote I/O
& RS232
Word #*
Bit # Definition Usage Notes
23 015 Reserved
24 015 X/YLine Head X Position From upper left corner.
25 015 X/YLine Head Y Position From upper left corner.
26 015 X/YLine Tail X Position From upper left corner.
27 015 X/YLine Tail Y Position From upper left corner.
2829 015 Reserved
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Table D.4 shows the function of each word in the reference window 13
(Toolset 1) configuration blocks.
Table D.4
Configuration Blocks #79 Reference Windows 13 (Toolset 1)
Remote I/O
& RS232
Word #*
Bit # Definition Usage Notes
0 015 Block Transfer Signature
1 07 Reserved
1 8 Enable 0 = Disabled
1 = Enabled
1 915 Reserved
27 015 Reserved
8 015 Feature 1 Search Window X
Location
Relative to the upper left corner.
9 015 Feature 1 Search Window Y
Location
Relative to the upper left corner.
10 015 Feature 1 Search Window Width
11 015 Feature 1 Search Window Height
1215 015 Reserved
16 07 Reserved
16 815 Feature 1 Score 0 = Minimum Value
255 = Maximum Value
17 015 Feature 2 Search Window X
Location
Relative to the upper left corner.
18 015 Feature 2 Search Window Y
Location
Relative to the upper left corner.
19 015 Feature 2 Search Window Width
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Configuration Blocks 4 6
(contd)
Configuration Blocks 7 9