Configuration Data
D–5
Tables D.3 shows the function of each word in the reference line 1–3
(Toolset 1) configuration blocks.
Table D.3
Configuration Blocks #4–6 – Reference Lines 1–3 (Toolset 1)
Remote I/O
& RS–232
Word #*
Bit # Definition Usage Notes
0 0–15 Block Transfer Signature
1 0–7 Reserved
1 8 Enable 0 = Disabled
1 = Enabled
1 9–15 Reserved
2–7 0–15 Reserved
8 0–7 X–Line Low Threshold/Gray Scale
Factor
0 – 63
0 – 39
If binary operation, value is used as the
threshold. If gray scale operation, value is
scale factor.
8 8–15 X–Line High Threshold/Gradient
Threshold
0 – 63
0 – 197
If binary operation, value is used as the
threshold high. If gray scale operation, value is
gradient threshold.
9 0–15 Reserved
10 0–15 X–Line Head X Position From upper left corner.
11 0–15 X–Line Head Y Position From upper left corner.
12 0–15 X–Line Tail X Position From upper left corner.
13 0–15 X–Line Tail Y Position From upper left corner.
14 0–15 Reserved
15 0–7 Y–Line Low Threshold/Gray Scale
Factor
0 – 63
0 – 39
If binary operation, value is used as the
threshold. If gray scale operation, value is
scale factor.
15 8–15 Y–Line High Threshold/Gradient
Threshold
0 – 63
0 – 197
If binary operation, value is used as the
threshold high. If gray scale operation, value is
gradient threshold.
16 0–15 Reserved
17 0–15 Y–Line Head X Position From upper left corner.
18 0–15 Y–Line Head Y Position From upper left corner.
19 0–15 Y–Line Tail X Position From upper left corner.
20 0–15 Y–Line Tail Y Position From upper left corner.
21 0–15 Reserved
22 0–7 X/Y–Line Low Threshold/Gray
Scale Factor
0 – 63
0 – 39
If binary operation, value is used as the
threshold. If gray scale operation, value is
scale factor.
22 8–15 X/Y–Line High Threshold/Gradient
Threshold
0 – 63
0 – 197
If binary operation, value is used as the
threshold high. If gray scale operation, value is
gradient threshold.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.