Owner's manual
Appendix C
Numerical Results Data
C–10
Table C.3
Numerical Results Data – Results Block 3
Word #
PI Backplane
RS–232
and
Bit #
Definition Usage Notes
Toolset 1 Toolset 2
Remote
I/O
194 458 42 0 – 15
Reference Window
#3X – Center
Centroid of enabled feature. 16 bit integer.
195 459 43 0 – 15
Reference Window
#3Y – Center
Centroid of enabled feature. 16 bit integer.
196 460 44 0 – 15
Reference Window
#3 Theta (Integer)
16 . 16 value. Refer to Appendix A. Only if 2 or 3
Features are enabled.
197 461 45 0 – 15
Reference Window
#3 (Fraction)
Only if 2 or 3 Features are enabled.
198 462 46 0
Reference Window
X1/Y1 Pass/Fail Bit
0 = Pass
1 = Fail
Feature #1 16 bit integer.
198 462 46 1
Reference Window
X2/Y2 Pass/Fail Bit
0 = Pass
1 = Fail
Feature #2 16 bit integer.
198 462 46 2
Reference Window
X3/Y3 Pass/Fail Bit
0 = Pass
1 = Fail
Feature #3 16 bit integer.
198 462 46 3
Combination
Pass/Fail Bit
0 = Pass
1 = Fail
0 if all enabled tools pass.
198 462 46 4 – 15 Not Used
199 463 47 0 – 15
Score Reference
Window #3,
Feature #1
200 464 48 0 – 15
Score Reference
Window #3,
Feature #2
201 465 49 0 – 15
Score Reference
Window #3,
Feature #3
202 – 209 466 – 473 50 – 57 0 – 15 Reserved
210 474 58 0 – 15 Reserved
211 475 59 0 – 15
Task Missed
Triggers
16 bit integer.
212 476 60 0 – 15
Task Masters
Faults – Most
Significant Word
32 bit integer. Increments if at least 1 tool fails.
Results Block #3 (cont’d)