Owner's manual

C
Appendix
C1
Numerical Results Data
There are 4 results blocks for each toolset. The following is an overview of
the blocks.
Block Number 1 Contains:
Block Transfer Signature
Discrete Output Copy
Brightness Probe
X/Y Reference Lines #1, #2, and #3
Feature Finder #1
Windows 18
Gages 18
Total Number of Triggers, Missed Triggers, and Master Faults
Block #2 Contains:
Block Transfer Signature
Windows 916
Gages 922
Windows 1724
Total Number of Triggers
Block #3 Contains:
Block Transfer Signature
Gages 2332
Feature Finders #2 and #3
Total Number of Triggers, Missed Triggers, and Master Faults
Block #4 (Remote I/O Port only) Contains:
Block Transfer Signature
Status Word
User Programmable Block Transfer Data
Total Number of Triggers
Results Block Overview