Owner's manual
Chapter 6
Using the Pyramid Integrator Backplane
6–8
CONTROL BLOCK 0MSG0:0
F1 Requested Size(element): 0
F2 Priority: HIGH
F3 Local/Remote: LOCAL
F4 Local Link Type: DH+
F5 Remote Link Type: N/A
F6 Station ID: Node# = 0
F7 Module ID: Class = CVIM Tw# = 1 Port# = 1
F8 Communication Command: TYPED READ
F9 Internal Data Table Addr: 0L9:0
F10External Data Table Addr: ”>rc,cb*”
Parameters: N/A
CONTROL BLOCK OMSG0:1
F1 Requested Size(element): 0
F2 Priority: HIGH
F3 Local/Remote: LOCAL
F4 Local Link Type: DH+
F5 Remote Link Type: N/A
F6 Station ID: Node# = 0
F7 Module ID: Class = CVIM Tw# = 1 Port# = 1
F8 Communication Command: TYPED WRITE
F9 Internal Data Table Addr: 0L9:0
F10External Data Table Addr: ”>w,cb*”
Parameters: N/A
If you are accessing results through a MicroVAX information processor, you
should use the standard library functions to access the data. The MicroVAX
library instructions are called up using a simplified “C” type language. For
example:
DTL__READ__W(Address, &Result, &Error);
Refer to the MicroVAX manuals for the available library routines.
Sample PLC–5/250 Program
(cont’d)
Obtaining Inspection Result
Information Using a MicroVAX
Information Processor