Owner's manual

Chapter 5
Using the RS232 Ports
542
11 (hex) = Stats 2 page displayed Toolset 1
12 (hex) = Page up same display Toolset 1
13 (hex) = Page down same display Toolset 1
15 (hex) = Image only displayed Toolset 2
16 (hex) = Failed tools displayed Toolset 2
17 (hex) = All tools displayed Toolset 2
18 (hex) = I/O page displayed Toolset 2
19 (hex) = Results page displayed Toolset 2
1A (hex) = Stats 1 page displayed Toolset 2
1B (hex) = Stats 2 page displayed Toolset 2
1C (hex) = Page up same display Toolset 2
1D (hex) = Page down same display Toolset 2
0B 13 Data
The data in this command specifies both the toolset and the display to be
viewed.
0B (hex) = Go on reject Toolset 1
0C (hex) = Freeze on first reject Toolset 1
0D (hex) = Freeze on all reject Toolset 1
0E (hex) = Freeze on next inspection Toolset 1
0F (hex) = Halt on reject Toolset 1
15 (hex) = Go on reject Toolset 2
16 (hex) = Freeze on first reject Toolset 2
17 (hex) = Freeze on all reject Toolset 2
18 (hex) = Freeze on next inspection Toolset 2
19 (hex) = Halt on reject Toolset 2
0B 14 Data
The data in this command specifies both the toolset and the display to be
viewed.
0B (hex) = Resume Toolset 1
0C (hex) = Reset Statistics Toolset 1
0D (hex) = Reset counters Toolset 1
12 (hex) = Page up Toolset 1
13 (hex) = Page down Toolset 1
Select Image Displayed (contd)