Owner's manual
Chapter 5
Using the RS–232 Ports
5–38
Use this command to read the results of the last inspection. Refer to
Appendix C for a description of the results blocks. Use one of the following
commands:
07 00 n times x y z
Where:
07 = Read Command
00 = Always 00
n times = Value for repeat read
x = 04 (Specifies Toolset #1)
05 (Specifies Toolset #1)
08 (Specifies CVIM module status)
10 (Specifies Results Block #1)
15 (Specifies Results Block #2)
y = 16 (Specifies Gage)
17 (Specifies Window)
18 (Specifies Reference Line)
19 (Specifies Reference Window)
1A (Specifies Light Probe)
z = Number of window or gage being read or block result
number.
n times07 00 04
Use this command to read the discrete bit results of toolset 1.
n times07 00 05
Use this command to read the discrete bit results of toolset 2.
n times07 00 10 Data
Use this command to read results blocks for toolset 1.
Where data = results block number.
n times07 00 15 Data
Use this command to read results blocks for toolset 2.
Where data = results block number.
Read Results Command