USER-PAK Option
Chapter 8
Defining Strings for Serial Ports and Viewports
8 – 6
Table 8.A (pt. 2 of 3)
Data Codes
Data Code➀ Subcodes (.s)➀
Description of field
RLn.0 X coordinate value of edge position on reference line.
RLn.s
RLn.1
Y coordinate value of edge position on reference line.
(n = 1 to 3)
(s = 0 to 4)
RLn.2
Pass/fail condition for reference line (1 = pass, 0 = fail).
(For Ref. Lines)
RLn.3
Theta from a reference line configured for “X–X then Y” or
“Y–Y then X” rotation compensation.
RLn.4 Number of faults detected.
RWn.0 Cumulative position: X coordinate value.
RWn.1 Cumulative position: Y coordinate value.
RWn.2
Cumulative angle (Q).
RWn.3 Cumulative pass/fail condition (1 = pass, 0 = fail).
RWn.4 Active feature #1 position X coordinate value.
RWn.5 Active feature #1 position Y coordinate value.
RWn.s
RWn.6
Active feature #1 score value.
RWn.s
(n = 1 to 3)
RWn.7
Active feature #1 pass/fail condition (1 = pass, 0 = fail).
(s = 0 to 16)
RWn.8
Active feature #2 position X coordinate value.
(For Ref.
RWn.9
Active feature #2 position Y coordinate value.
Windows)
RWn.10
Active feature #2 score value.
RWn.11 Active feature #2 pass/fail condition (1 = pass, 0 = fail).
RWn.12 Active feature #3 position X coordinate value.
RWn.13 Active feature #3 position Y coordinate value.
RWn.14 Active feature #3 score value.
RWn.15 Active feature #3 pass/fail condition (1 = pass, 0 = fail).
RWn.16 Number of faults detected.
Sn.0 Formula/tool (n) statistics: number of samples.
Sn.s➁
Sn.1 Formula/tool (n) statistics: minimum reading value.
(n = 1 to 112)
(s = 0 to 4)
Sn.2
Formula/tool (n) statistics: maximum reading value.
(s = 0 to 4)
Sn.3
Formula/tool (n) statistics: mean value.
(For Statistics)
Sn.4 Formula/tool (n) statistics: standard deviation value.
➀The letter n = tool or formula number (as appropriate). The letter s = operand
subcode.
➁ Where n = 0 to 56, the letter n specifies the formula number, if the formula of that
number is enabled (the MATH -PAK option package, Cat. No. 5370–CMPK, must be
installed to use formulas). Otherwise, the letter n specifies the tool number and
type, as follows:
For n = 1-8 – n specifies: windows 1-8, respectively.
For n = 9-16 – n specifies: gages 1-8, respectively.
For n = 17-24 – n specifies: windows 9-16.
For n = 25-32 – n specifies: gages 9-16.
For n = 33-40 – n specifies: windows 17-24.
For n = 41-56 – n specifies: gages 17-32.